24
Quadra-Fire • Sapphire • 7055-116 Rev. D • 6/11
Fire Risk.
Explosion Risk.
• If the information in these instructions is
not followed exactly, a fi re, explosion or
production of carbon monoxide may result
causing property damage, personal injury
or loss of life.
• The qualifi ed service agency is responsible
for the proper installation of this conversion
kit. The installation is not proper and
complete until the operation of the converted
appliance is checked as specifi ed in the
manufacturer’s instructions supplied with
the kit.
WARNING
A
B
C
Mounting Screws
Pressure Regulator Tower
Diaphragm
E
D
F
Rubber Gasket
Screws
Identification Label
Figure 6.6 Turn control knob to the OFF position, ensure that
gas supply to the valve has been turned off. Using a Torx
TH20, or slotted screwdriver, remove the three pressure reg-
ulator mounting screws (A), pressure regulator tower (B),
and diaphragm (C).
Figure 6.6 Ensure that the rubber gasket (D) is properly posi-
tioned and install the new HI/LO pressure regulator assem-
bly to the valve using the new screws (E) supplied with the
kit. Tighten screws securely. (Reference torque = 25 in./lb.)
Install the enclosed identifi cation label (F) to the valve body
where it can be seen.
Fill out the conversion label and attach it to the valve cover.
WARNING
Fire Risk.
Explosion Risk.
Gas Leak Risk.
• Rubber gasket must be seated properly on valve
face.
• Do no install a valve or regulator that has been
dropped.
2. Valve Regulator Replacement
Figure 6.5 Remove upper and lower back shield. Loosen
the set collars on the extension rods with the 3/32 in. Allen
wrench. Remove the rods and adapter caps.
Fire Risk.
Explosion Risk.
• Disconnect any electrical cords and
turn off gas supply to unit before
proceeding if converting fuel on an
appliance already fully installed.
WARNING
Upper & Lower Rear Shields
Hook into Slots on the Appliance
Extension Rods
Adapter Caps
Set Collars