Figure 8
NOTE: On vertical venting
configurations you may
want to install the flue re-
strictor (385-128). See flue
restrictor installation in-
structions.
Flue Restrictor Instructions
1. Locate the flue restrictor which is in the manual
bag.
Figure 9
2. Break the Flue Restrictor into two pieces. Do this
by bending the part back and forth until it breaks
(see Figure 10).
V
CAP
FLUE
RESTRICTOR
STRAIGHT UP
VERTICAL VENTING
V (FT.)
50' MAX. (15.2 M)
Figure 10. Flue Restrictor
BREAK
HERE
1 2 3 4 5
SETTINGS
1 2 3 4 5
4. Center the Flue Restrictor on vent and secure in
place using two self-tapping screws (see Figure 11).
STRAIGHT OUT
HORIZONTAL VENTING
H
Max. Run
24" (610 mm)
Figure 12.
H
3. Match the amount of
vertical you have in the
system with the chart to
find the appropriate po-
sition to set the Flue Re-
strictor.
Figure 11
- CHART -
Vertical Settings
4' 1-1
8' 1-2
15' 2-2
20' 2-3
25' 3-3
30' 4-3
35' 4-4
40' 4-4
50' 4-5