Quadra-Fire QV32EV-B Indoor Fireplace User Manual


 
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05
10
B
+
B
A
-
A
LAMP
LAMP
FLAME M0TOR
120 VAC
LAMPS
REMOTE HEAT
CONTROL
REMOTE OR
WALL ON/OFF
SWITCH
12VDC
SUPPLY
POWER
WHITE
HEAT SWITCH
OPTIONAL
-12VDC
SPEED
CONTROL
R2
D1
DIODE
THERMOSTAT
RELAY
DIMMER
PE
N
L1
L2
120 V
120 V
240 V
TERMINAL STRIP
120 VAC PLUG OR 120/240
HARD WIRED
3 PIN WIRING
HARNESS
120 VAC
BLACK
RED
-12VDC
HIGH LIMIT
BLOWER
BLOWER
HEATER 1
240 VAC
HIGH LIMIT
BLOWER
HEATER 1
HEATER 2
BLACK
RED
POWER NEUTRAL MUST NOT
CONNECT TO VIRTUAL NEUTRAL
OF HEATERS OR BLOWER IN
240VAC VERSION
120VAC - 240VAC 60 HZ SPLIT-PHASE
Figure 4.1 120V/240V Wiring Diagram
C. 240VAC Hardwire Installation
Turn off circuit breaker.
• Access knockout.
Remove the access cover plate.
Disconnect the power cord from the terminal block.
Remove the knockout and install the cable clamp (not
provided) into the hole.
Feed 8 in. of service wire through the cable clamp and
secure.
Connect the black wire from the service to the L1
terminal.
Connect the red wire from the service to the L2
terminal.
Connect the white wire from the service to the N
terminal.
Connect the green (ground) from the service to the GND
terminal.
Optional wall switch wiring is to be done at this time.
Replace access cover plate.
D. Wall Switch Wiring (12VDC)
*Do not connect wires to 120/240VAC* (hardwired heat-
ers only)
Turn off circuit breaker.
• Access knockout.
Remove the access cover plate.
Feed 16 in. of service wire through the cable clamp and
secure.
Low voltage wire can be used for the wall switch
connection.
Locate the loop of blue wire on the accessory
connector.
Cut the loop and connect one side to one of the wall switch
wires and the other side to the other wire for the switch.
Replace the access cover plate.
Run the wall switch wire to the wall box and connect to a
wall switch (WSK-21 & WSK-21-W)..