R
August 20, 2009
250-7251G
Page 23
Castile Pellet Insert
1. A 12 volt AC thermostat is required to operate this
pel
let appliance. You may use the included wall mount
thermostat or purchase an optional programmable
thermostat or remote control. The included thermostat
is equipped with an adjustable heat anticipator. The
current rating is .05 amps. The anticipator needs to
be adjusted to the lowest setting available.
2. When mounting a thermostat on a wall, be sure to follow
your thermostat installation instructions carefully.
NOTE: Thermostat must be mounted level for accu-
rate readings. The thermostat should be mounted
on an inside wall and not in direct line with the
appliance convection air. Remove any packaging
from inside the thermostat before using.
NOTE: If the thermostat is located too close to
the appliance, you may need to set the tempera-
ture setting slightly higher to maintain the desired
temperature in your home.
3. There is a 4 screw terminal block located on the junc-
tion box to the left of the power cord inlet. The center
2 screws are for the thermostat wires. The outer 2 are
the mounting screws for the terminal block. Figure
23.1.
H. Thermostat Installation
Figure 23.1
Shock hazard.
• Do NOT
remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
•
Do NOT route cord under or in front of appli-
ance.
CAUTION
Control Box
Junction Box
Reset Button
Heat Output
Switch
Power Cord
Outlet
Thermostat
Block
Fuse
Red Call
Light
Red/
Gre
en/A
mbe
r Light
Blu
e Light