Quadra-Fire CASTILE-MBK Stove User Manual


 
Page 8
250-6422D
October 11, 2005
R
Castile Pellet Stove
R
R
Straight Back Against
Wall
Inches Millimeters
A
Back Wall to Appliance 2 51
B
Side Wall to Appliance 6 152
Corner Installation
Inches Millimeters
C
Walls to Appliance 2 51
Vertical Installation
Inches Millimeters
D
Back Wall to Flue Pipe 3 76
E
Side Wall to Cast Top 6 152
F
Back Wall to Appliance 8 203
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
Corner Installation
Inches Millimeters
G
Walls to Appliance 2 51
H
Side Wall to Flue Pipe 3 76
Alcove Installation
Inches Millimeters
Minimum Alcove Height 43 1092
Minimum Alcove Side Wall
6 152
Minimum Alcove Width
38 965
Maximum Alcove Depth
36 914
Dimension to Corner
Inches Millimeters
I
Flue Center Line 10-3/8 264
J
Back of Top Vent Adapter 9-1/8 232
B. Clearances to Combustibles (UL and ULC)
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
WARNING
Failure to comply may cause house fire.
NOTE:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
J
I
C
L
C
C
D
E
F
G
G
H
H
A
B