Page 10
7022-122
January 19, 2011
R
Castile Pellet Insert
Fire Risk.
Comply with all minimum clear-
ances to combustibles as speci-
fi ed.
WARNING
Failure to comply may cause
house fi re.
NOTE:
• Illustrations refl ect typical installations
and are FOR DESIGN PURPOSES
ONLY.
• Illustrations/diagrams are not drawn to
scale.
• Actual installation may vary due to
individual design preference.
A
C
B
D
C
B
0 in. Clearance To Exposed Section And Face Trim
B. Clearance To Combustibles, UL and ULC
Inches Millimeters
A Top of Hopper Top Vent 2.0 51
Rear Vent 2.5 64
B Side of Hopper Top or Rear Vent 2.0 51
C Back of Hopper Top or Rear Vent 4.0 102
D Vent Pipe to Combustible Top or Rear Vent 3.0 76
12 in
(305mm)
Combustible
Mantel
6 in
(152mm)
Outside Air
Top Vent:
2 in. (51mm)
Rear Vent:
2.5 in (64mm)
Back of Hopper:
4 in (102mm)
Vent Pipe to
Combustibles:
3 in (76mm)
INSTALLED AS A BUILT-IN UNIT
Shown with Rear Vent and Outside Air
Figure 10.1
Figure 10.2
AS A BUILT-IN
NOTE: All Clearances are Minimum Clearances
Must be installed in a non-tapered enclosure.