Procom V50HYLD Indoor Fireplace User Manual


 
SERVICE INSTRUCTIONS
CLEARANCE TO COMBUSTIBLES
ELECTRICAL CONNECTION
A
15 AMP, 120 Volt, 60Hz circuit with a properly grounded
outlet is required. Preferably, the heater will be on a
dedicated circuit. Other appliances on the same circuit
may cause the circuit breaker to trip or the fuse to blow
when the heater is on operation. The unit comes standard
with a 6’ (1828mm) long three wire cord exiting from the
rear of the fireplace. Plan the installation to avoid the use
of an extension cord. If an extended cord must be used, it
must be a minimum 16 AWG three wire with grounding
type plug connector and rated no less than 1900 Watts.
Back………………2”/50.8mm
Sides……………..6”/156.4mm
Floor……………..0”/0mm
Top……………….24”/610mm
WARNING: Electrical outlet wiring
must comply with local building
codes and all other applicable
regulations to reduce the risk o
f
fire, electrical shock and injury.
WARNING: Do not use this
fireplace if any part of it has been
under water. Immediately call a
qualified service technician to
inspect the fireplace and replace
any part of the electrical system i
f
necessary.
ELECTRICAL SPECIFICATIONS
Voltage………………120 VAC/60Hz
Total Amps…………..11.3 Amps
Total Watts…………..1345 Watts
Heater Ratings………1200 Watts
WARNING: Disconnect powe
r
before attempting any
maintenance or cleaning to
reduce the risk of fire, electrical
shock or personal injury
REPLACING LIGHT BULBS
This fireplace uses two clear 120 Volt, 60 Watt, E-12
socket base light bulbs (small base, chandelier candle
type).The 60 Watt bulbs are located under the log
set/ember bed. For convenience, if one of the bulbs
b
urns out, it may be a good idea to replace both of the
light bulbs.
1. Turn off power to the unit by unplugging the powe
r
cord.
2. Let fireplace cool if it has been operating.
3. Open the front door by pulling the handle.
4. Remove the two screws that secure the log set in
position.
WARNING: Do not exceed 60
Watts per bulb. Use of higher
rated bulbs may result in a fire
causing property damage and
personal injury.
3
5. Remove the two screws of the front baffle and
take them out.
6. Examine the bulbs to determine which one
needs to be replaced.
7. While holding the socket, unscrew the defective
bulb(s).
8. Install the new light bulb(s) by holding the socket
and screwing them in.
9. Reinstall the baffle log set and screen. Follow
the above procedure in reverse order.