19
TROUBLESHOOTING
Continued
REMEDY
1. Ventilate room. Stop using odor
causing products while heater is
running
2. Locate and correct all leaks (see
Checking Gas Connections, Page
9)
1. Open window and/or door for, venti-
lation
2. Contact local propane/LP gas com-
pany
3. Clean ODS/pilot (see Cleaning Page
14)
1. Locate and correct all leaks (see
Checking Gas Connections, Page
9)
1. Remove foreign matter
2. Locate and correct all leaks (see
Checking Gas Connections, Page
9)
1. Refer to Air for Combustion and Ven-
tilation requirements, Page 5
POSSIBLE CAUSE
1. Heater is burning vapors from paint,
hair spray, glues, etc. (See IMPOR-
TANT statement at beginning of
troubleshooting)
2. Gas leak. See WARNING Statement
at beginning of troubleshooting
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See WARNING Statement
at beginning of troubleshooting
1. Foreign matter between control valve
and burner
2. Gas leak. See WARNING Statement
at beginning of troubleshooting
1. Not enough combustion/ventilation
air
OBSERVED PROBLEM
Heater produces unwanted odors
Heater shuts off in use (ODS
operates)
Gas odor exists even when heater is
shut off
Gas odor during combustion
Moisture/condensation on windows