TO TURN OFF GAS
TO APPLIANCE
Push in gas Control Knob slightly and
turn clockwise the OFF position. Do
not force.
When electric power is available and
electric operation is desired, turn clock-
wise to OFF position for one minute.
Then press down knob and rotate clock-
wise to ELECTRIC position.
Do not operate between locked
position.
MANUAL LIGHTING
PROCEDURE
(match light)
1. Open front door.
2. Follow steps 1 through 5 under
MANUAL OPERATING Lighting
Instructions.
3. With Control Knob in PILOT/IGN
position, strike match, and hold
near pilot. Press in Control Knob,
pilot should light.
4. Keep Control Knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release Control Knob. Fol-
low step 9 under MANUAL OPER-
ATING Lighting Instructions.
Figure 16 - Manual Control
5. Wait five (5) minutes to clear out
any gas. Then smell for gas, in-
cluding near the floor. If you smell
gas, STOP! Follow B in the safety
information on page 11. If you do
not smell gas, go to the next step.
6. Push in gas control slightly and
turn counterclockwise to PI-
LOT/IGN and depress for five (5)
seconds.
NOTE: The first time that the
heater is operated after connect-
ing the gas supply, the control
knob should be depressed for
about thirty (30) seconds. This will
allow air to bleed from the gas
system.
7. With Control Knob pressed in, push
and release the ignitor button.
This will light the pilot. If needed,
keep pressing ignitor button until
pilot lights.
8. Keep Control Knob depressed for
ten (10) seconds after lighting
pilot. If pilot goes out, repeat steps
6, 7 and 8.
9. Turn counterclockwise to ON
position. Do not operate between
locked positions.
MANUAL OPERATING
INSTRUCTIONS
Continued