OBSERVED PROBLEM
POSSIBLE CAUSE REMEDY
Delayed ignition burner.
1. Manifold pressure is too low.
2. Burner orifice is clogged.
1. Contact local gas company.
2. Clean burner (see Cleaning and
Maintenance, pages 11).
Burner backfiring during combustion.
1. Damaged burner.
2. Gas regulator is defective.
1. Clean burner orifice (see Cleaning
and Maintenance, page 11).
2. Replace gas regulator.
Slight smoke or odor during initial
operation.
1. Residues from manufacturing
processes.
2. Not enough air.
3. Gas regulator is defective.
1. Problem will stop after a few hours
of operation.
2. Check burner for dirt and debris.
If found, clean burner (see Cleaning
and Maintenance, pages 11).
3. Replace gas regulator.
Dark residue on logs or inside of
fireplace.
1. Improper log placement.
2. Air holes at burner inlet are blocked.
3. Burner flame holes are blocked.
1. Properly locate logs (see Installing
Logs, page 9).
2. Clean out air holes at burner inlet.
Periodically repeat as needed.
3. Remove blockage or replace burner.
Heater produces a clicking/ticking
noise just after burner is lit or shut off.
1. Metal expanding while heating or
contracting while cooling.
1. This is common with most
heaters. If noise is excessive,
contact qualified service person.
Btu 20000/25000 20000/25000
Gas Type LP Gas Natural Gas
Ignition Piezo Piezo
Manifold Pressure 8"W.C. 3"W.C.
Inlet Gas Pressure
(In. of water)*
Maximum 14" 10.5"
Minimum 11" 5"
Dimensions, Inches (H
×
W
×
D)
Heater 33 9/16”
×
23 1/8”
×
13 9/16” 33 9/16”
×
23 1/8”
×
13 9/16”
Carton 36 7/8”
×
26 1/8”
×
16 1/2” 36 7/8”
×
26 1/8”
×
16 1/2”
Weight, lbs
Heater 73 73
Shipping 84 84
*For purposes of input adjustment
SL250TYLA-D SN250TYLA-D
SPECIFICATIONS