CLEARANCE TO COMBUSTIBLES
ELECTRICAL CONNECTION
A 10 AMP, 220 Volt, 50Hz circuit with a properly grounded outlet
is required. Preferably, the fireplace will be on a dedicated
circuit. Other appliances on the same circuit may cause the
circuit breaker to trip or the fuse to blow when the heater is on
operation. The unit comes standard with a 6 (1828mm) long
three wire cord exiting from the rear of the fireplace. Plan the
installation to avoid the use of an extension cord. If an exten-
sion cord must be used, it must be a minimum 1.0 mm
2
three
wire with grounding type plug connector and rated no less
than 1900 Watts. The cord shall not be more than 20 feet in
length.
ELECTRICAL SPECIFICATIONS
Sides....................................0 mm 0 inches
Floor.....................................0 mm 0 inches
Top........................................0 mm 0 inches
Voltage:220 VAC, 50 Hz
Total Amps:6.3 Amps
Total Watts:1380 Watts
Heater Rating:1200 Watts
WARNING: Electrical outlet wir-
ing must comply with local build-
ing codes and all other appli-
cable regulations to reduce the
risk of fire, electrical shock and
injury.
WARNING: Do not use this fire-
place if any part of it has been
under water. Immediately call a
qualified service technician to
inspect the fireplace and re-
place any part of the electrical
system if necessary.
3
LOCATING YOUR ELECTRIC FIREPLACE
Your new freestanding electric fireplace may be installed vir-
tually anywhere in your home. However when choosing a
location for your new electric fireplace, ensure that the gen-
eral instructions are followed. For best effect results, install
the electric fireplace out of direct sunlight.