Procom MN100TPA Gas Heater User Manual


 
17
SPECIFICATIONS
Btu(available)
Gas Type
Ignition
Pressure Regulator setting
Inlet Gas Pressure* (inches of water)
Maximum
Minimum
Dimensions, Inches (HxWxD)
Heater
Carton
Weight (pounds)
Heater
Shipping
MN100HPA
5,500/10,000
Natural Only
Piezo
6" W.C.
10.5"
7"
19-1/8
×
14-1/8
×
6-3/8
22
×
16-3/4
×
8-1/8
13
16
Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).
* For purposes of input adjustment.
TECHNICAL SERVICE
You may have further questions
about installation, operation, or
troubleshooting. If so, contact
PRO-COM through phone number 1-
877-886-5989.The information is
listed on the front of manual.
SERVICE HINTS
When Gas Pressure Is Too
Low
l Pilot will not stay lit
l Burner will have delayed ignition
l Heater will not produce specified
heat
When Gas Quality Is Bad
l Pilot will not stay lit
l Burner will produce flames and
soot
l Heater will backfire when lit
You may feel your gas pressure is
too low or the gas quality is poor. If
so, contact your local natural gas
supplier.
REPLACEMENT PARTS
Note: Use only original replacement
parts. This will protect your warranty
coverage for parts replaced under
warranty.
PARTS UNDER WARRANTY
Contact authorized dealer from
whom you purchased this product.
If they are unable to supply original
replacement part(s), call the num-
ber on the front of this manual. When
contacting your dealer or PRO-COM,
have ready:
l your name
l your address
l model and serial numbers of
your heater
l how heater was malfunctioning
l type of gas used (propane/LP or
natural gas)
l purchase date
l warranty card
Usually, we will ask you to return the
defective part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this
product. If they cant supply original
replacement part(s), contact PRO-
COM through phone number 1-877-
886-5989.
MN060HPA
6,000
Natural Only
Piezo
6" W.C.
10.5"
7"
19-1/8
×
14-1/8
×
6-3/8
22
×
16-3/4
×
8-1/8
12
15
MN100TPA
10,000
Natural Only
Piezo
6" W.C.
10.5"
7"
19-1/8
×
14-1/8
×
6-3/8
22
×
16-3/4
×
8-1/8
13
16
ACCESSORIES
Purchase these heater accesso-
ries from your local dealer. If they
can not supply these accessories,
contact PRO-COM for information.
You can also write to the address
listed on the front of this manual.
EQUIPMENT SHUTOFF VALVE
For all models. Equipment shutoff
valve with 1/8" NPT tap.
FLOOR MOUNTING STAND
Models MN060HPA,MN100HPA,
MN100TPA
For locating heater on the floor away
from a wall. Complete installation
instructions provided with floor
mounting stand.