3-3 Electrical Connections
CAUTION: before connecting the appliance, make sure that the supply
power line is disconnected from the network.
General Power Supply Characteristics
Neutral mode TT and TN.S; the circuit of the heat pump must be
connected to the earth circuit
Connections
The electric installation must be carried out by a qualified professional or
electrician
The power supply of the heat pump must come from an independent
circuit and have the appropriate circuit protection.
The controller must be installed on an indoor wall in an easily accessible
area.
Electrical Protection
Circuit breaker curves D or standard fuse protection Am, gauged with
16A
Differential protection of 30mA
Connection to an Electrical Plug
The heat pump comes packaged with an electric cable and plug.
The plug must be safe, protected from rain and water and the condition
checked regularly
Before starting the heat pump hot water cylinder, it is important to fully read this
manual and understand the operation and the settings.