Baxi Potterton FSB 30 HE Boiler User Manual


 
1.0 Operating the Boiler
3
© Baxi Heating UK Limited 2008
1.1 Operating the Boiler
1. Hinge down the facia cover (Fig. 1).
2. Turn on the main gas and electricity supplies to the
boiler. The Mains On light ( ) will illuminate green
(Figs. 1 & 2).
3. Set the central heating control knob to the required
setting (Fig. 1). (The optimum boiler setting depends
upon type of system, external controls and your
requirements. Your installer will be able to advise you on
this matter.)
4. When the system control(s) call for heat the fan will
start to run and after a short period the ignition spark will
commence. Sparking will continue until the flame is
established then stop automatically. Check that both the
Mains ON light ( ) and Boiler ON light ( ) are
illuminated green (Figs. 1 & 2).
5. The boiler can be switched off by turning all external
controls or the optional integral timer Heating and Hot
Water settings to OFF.
1.2 To shut down the Boiler
1. Turn off the electricity supply to the boiler at the
system isolation switch and turn off all external controls.
2. Your installer should have demonstrated how to shut
down the boiler - if not he will be able to advise you.
1.3 Frost Protection
1. The boiler has integral frost protection. It is
recommended that the installer fits a suitable device to
also protect the system if required. The boiler must be
turned ON at the system isolation switch for frost
protection.
1.4 In Operation
1. The Promax FSB 30 HE is a high efficiency “condensing
boiler”. In common with other condensing boilers its
exceptional efficiency means the flue gases are cooled to
such an extent that a plume of water vapour is often
visible at the outside flue terminal. The amount produced
depends on system design, product use and outside air
temperature but it is not harmful to the individual or the
working of the boiler in any way.
2. The boiler incorporates a condensate pump which
may operate at any time, for up to 30 seconds, even
when the boiler is not running.
1.5 In the Event of a Gas Leak
1. If a gas leak occurs or is suspected, turn off the gas
supply at the meter control.
2. Do not operate electric light or power switches, either
off or on and ventilate the property.
3. Contact your gas supplier.
Low
High
Reset
Low
High
Reset
Central Heating
Control Knob
(No OFF Position)
Turn the Central Heating Control Knob clockwise
to increase or anticlockwise to decrease the
boiler flow temperature.
Reset Button
The Reset Button should extingush the
Flame Failure Light and restore normal
operation.
Mains On
(Green Light)
This indicates that there is electricity to the Boiler.
Burner On
(Green Light)
This indicates that the Burner has fired up
and is heating your system.
Flame Failure
(Red Light)
If Flame Failure Light is ON press the Reset
Button. If Flame Failure occurs persistently
consult your Installer or Service Engineer.
Fig. 1
Fig. 2
Facia Cover
Key to Controls
Optional
Integral Timer
User Operating Guide
and Serial Number