Pioneer MUH-GA25VB Air Conditioner User Manual


 
6
PART NAMES AND FUNCTIONS
2
( )
Air inlet
Air outlet
Drain outlet
Piping
Drain hose
back : MUH-GA20VB
back and side : MUH-GA25VB
MUH-GA35VB
OUTDOOR UNIT
MUH-GA20VB -
MUH-GA25VB -
MUH-GA35VB -
E1
E1
E1
ACCESSORIES
MUH-GA20VB-
MUH-GA25VB-
MUH-GA35VB-
E1
E1
E1
Drain socket
1
<Outdoor unit: MUH type>
1
SPECIFICATION
3
Capacity
Dehumidification
Outdoor air flow
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Compressor motor current
Fan motor current
Model
Output
Winding
resistance (at 20:)
Model
Winding
resistance (at 20:)
Dimensions WOHOD
Weight
Sound level
Fan speed
Fan speed regulator
Refrigerant filling
capacity (R410A)
Refrigeration oil (Model)
Thermistor RT61 (at 0:)
kW
R/h
K /h
A
A
W
A(kW)
%
A
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
k"
MUH-GA20VB -
E1
Single phase
230V,50Hz
1800
10
21
0.25
RN092VHSHT
600
C-R 3.87
C-S 6.14
RA6V21-AD
WHT-BLK 366
BLK-RED 274
800o550o285
32
47
745
1
0.65
350 (NEO22)
33.18
Cooling
2.3
0.9
3.00
680
99
2.76
3.22
Heating
2.5
2.86
655
100
2.62
3.62
MUH-GA25VB -
E1
Single phase
230V,50Hz
1902
10
22
0.33
RN104VHSHT
700
C-R 3.40
C-S 4.56
RA6V33-KB
WHT-BLK 215
BLK-RED 307
800o550o285
32
49
855
1
0.80
350 (NEO22)
33.18
Cooling
2.65
1.1
3.43
785
100
3.10
3.23
Heating
3.0
3.43
785
100
3.10
3.66
MUH-GA35VB -
E1
Single phase
230V,50Hz
1902
10
27
0.33
RN135VHSHT
900
C-R 2.79
C-S 3.36
RA6V33-KB
WHT-BLK 215
BLK-RED 307
800o550o285
35
49
855
1
0.80
620 (NEO22)
33.18
Cooling
3.5
1.7
4.65
1,050
98
4.32
3.21
Heating
3.7
4.34
980
98
4.01
3.63
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity
Coefficient of performance (C.O.P)
Outdoor unit power supply
Function
Outdoor model
NOTE: Test conditions are based on ISO 5151.
Cooling : Indoor DB27°C WB19°C Heating : Indoor DB20°C
Outdoor DB35°C WB24°C Outdoor DB 7°C/WB 6°C
Indoor-Outdoor piping length : 5m
OB387-1.qxp 05.2.21 10:03 AM Page 6