Philips RAMA FRESNEL & PC RANGE Indoor Furnishings User Manual


 
Version 5: September 2010 © Philips Selecon All Rights Reserved
YOKE PIVOT ADJUSTMENT
The yoke on the Rama range can be positioned anywhere in the channel that runs the length of the luminaire.
This is useful to achieve the best balance if using a colour changer or other accessory mounted on the front of
the luminaire, or to fit the luminaire in space restricted positions.
The yoke balance point is factory set on the lamp house for normal applications. To move the yoke, loosen the
M8 bolt at the bottom pivot point of the yoke on the right side of the luminaire. Release the tilt locking clamp on
the left side of the luminaire, and slide the yoke to the required position. Check the yoke is evenly positioned on
each side and tighten the M8 bolt, and the tilt locking clamp. To return the yoke to its original balance point,
align the yoke to the balance point marked on the focus reference scale.
PAN AND TILT ADJUSTMENT
Rama 150 Fresnel and PC, Rama 175 Fresnel and PC
To pan your luminaire loosen the yoke nut and bolt holding the hookclamp onto the yoke and adjust the yoke as
required, then retighten the yoke nut and bolt.
The nylock nut that secures the yoke on the opposite side to the tilt handle sets the tilt lock friction. The tilt
friction can be adjusted by loosening or tightening up the nylock nut. To tilt your luminaire, turn the tilt lock knob
clockwise, tilt the luminaire to the position required, and then turn the tilt lock knob anticlockwise. A tilt angle
reference scale is provided on the locking clamp disc to prefocus the luminaire if desired.
Please note that as the handles and integrated safety bond on the Rama range can reach high temperatures
depending on the position or orientation of the luminaire, and that gloves should always be worn when focusing.
Rama 150 FFT Fresnel and PC, Rama 175 FFT HP Fresnel and PC
The Rama is suppled with an FFT pan assembly on the yoke to facilitate fast adjustment. To pan your luminaire
turn the pan locker a ¼ turn clockwise and adjust the yoke as required, then turn the pan locker a ¼ turn
anticlockwise to set the position. A pan angle reference scale is provided on the FFT pan assembly to prefocus
the luminaire if desired.
The nylock nut that secures the yoke on the opposite side to the tilt handle sets the tilt lock friction. The tilt
friction can be adjusted by loosening or tightening up the nylock nut. To tilt your luminaire, turn the tilt lock knob
clockwise, tilt the luminaire to the position required, and then turn the tilt lock knob anticlockwise. A tilt angle
reference scale is provided on the locking clamp disc to prefocus the luminaire if desired.
ACCESSORIES
Suspension Hook Clamp (Order Code: 20HC)
Lens Safety Mesh (Order Code: 20SM6)
Colour Frame the luminaire is supplied with a colour frame 186 x 190mm. Additional colour frames are
available (Order Code: 20CFRA12).
Barndoor (Order Code: 20BDSF12)
EARTH TEST POINT
There is an earth test point located on the rear housing of the Rama. The earth test point is the silver machine
screw located on the right side of the rear housing, and is indicated by an earth symbol. To test the earth of the
Rama, place the test probe on the silver machine screw, and perform the earth test.
CLEANING
Open the down-swinging door, and clean the lens and/or reflector with a soft lint-free cloth.
This is the only maintenance task, which can be safely carried out by non-approved personnel.
Refer below Safety & Maintenance note.
SAFETY & MAINTENANCE
Philips Selecon has manufactured this luminaire in accordance with recognised best practices to recommended
international safety standards. It is your responsibility to maintain this luminaire in good and safe working
condition.
Repairs should only be carried out by suitably qualified persons. Do not operate the luminaire with cracked
lens, damaged cables etc. Consult your Philips Selecon distributor for assistance. Only replace damaged parts
with authorised Philips Selecon spares.
N.B. Luminaire Cable your Philips Selecon luminaire is fitted with a special heat-resistant, flexible cable,
replace with genuine Philips Selecon spare part cable kit only refer to your Philips Selecon distributor.
(Replacement cables are supplied complete with necessary terminal connectors).