CDM/TC
Philips MasterColor
®
Ceramic Metal Halide 4000K Tubular
Single-Ended T4 Lamps
Ordering Data
A
NSI Approx. Approx.
P
roduct Pkg. Nom. Ballast Initial Mean
N
umber Ordering Code Qty. Watt. Code Lumens
1
L
umens
2
C
RI
2
0883-5 CDM35/TC/842 12 39 M130/E 3300 2640 85
20885-0 CDM70/TC/942 12 70 M139/E 5900 3840 90
W
ARNINGS,CAUTIONSAND OPERATING
I
NSTRUCTIONS for MasterColor
®
C
eramic Metal Halide
L
amps:Single-Ended CDM-T G12,CDM-TCG8.5 (Universal);
Double-Ended CDM-TD RX7 (Horizontal ± 45º,Enclosed
Fixtures Only)
R
“WARNING:These lamps can cause serious skin burn and
eye inflammation from short wave ultraviolet radiation if outer
envelope of the lamp is broken or punctured.Do not use where
people will remain for more than a few minutes unless adequate
shielding or other safety precautions are used. Certain lamps that
w
ill automatically extinguish when the outer envelope is broken or
p
unctured are commercially available.”This lamp complies with FDA
r
adiation performance standard 21 CFR subchapter J.(USA:21CFR
1
040.30 Canada:SOR/DORS/80-381)
I
f the outer bulb is broken or punctured,turn off at once
a
nd replace the lamp to avoid possible injury from
hazardous short wave ultraviolet radiation.Do not scratch
the outer bulb or subject it to pressure as this could cause
the outer bulb to crack or shatter.A partial vacuum in the
outer bulb may cause glass to fly if the envelope is struck.
WARNING:The arc-tube of metal halide lamps are designed to
operate under high pressure and at temperatures up to 1000º C and
can unexpectedly rupture due to internal or external factors such as a
ballast failure or misapplication If the arc-tube ruptures for any reason,
t
he outer bulb may break and pieces of extremely hot glass might be
d
ischarged into the surrounding environment.If such
a
rupture were to
h
appen,THEREISA RISK OF PERSONAL
I
NJURY,PROPERTY
D
AMAGE,BURNSAND FIRE.
C
ertain lamps that will retain all the glass particles should
inner arc-tube rupture occur are commercially available
from Philips Lighting Company.
RELAMP FIXTURESAT OR BEFORETHE END OF
RATED LIFE.Allowing lamps to operate until they fail is
not advised and may increase the possibility of inner arc
tube rupture.
This lamp contains an arc tube with a filling gas containing
less than 10 nCi of Kr-85 and is distributed by Philips Lighting
Company,a division of Philips Electronics NorthAmerica
C
orporation,Somerset,New Jersey,08875.
C
AUTION:TO REDUCETHE RISK OF PERSONAL INJURY,
P
ROPERTY DAMAGE,BURNSAND FIRE RESULTING FROM
A
N ARC-TUBE RUPTURETHE FOLLOWING LAMP
OPERATING INSTRUCTIONS MUST BE FOLLOWED:
LAMP OPERATING INSTRUCTIONS:
1.RELAMP FIXTURES AT OR BEFORETHE END OF RATED LIFE.
Allowing lamps to operate until they fail is not advised and may
increase the possibility of inner arc tube rupture.
2.Use only in fully enclosed fixtures capable of withstanding particles
of glass having temperatures up to 1000º C. Lens/diffuser material
must be heat resistant.Consult fixture manufacturer regarding the
suitability of the fixture for this lamp.
3.Do not operate a fixture with a missing or broken lens/diffuser.
4.Operate lamp only within specified limits of operating position.
5.Before lamp installation/replacement,shut power off and allow
lamp and fixture to cool to avoid electrical shock and potential
burn hazards.
6.Use only auxiliary equipment meeting Philips and/or ANSI standards.
Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B.For total supply load refer to ballast manufacturers
electrical data.
C.Operate CDM-T (G12 base) lamps only on thermally
protected ballasts.
D.Operate CDM-TC lamps (G8.5 base)only on
thermally protected electronic
ballasts
E.Operate CDM-T (G12 base) 39W/842 lamps only on
thermallly protected electronic
ballasts
7.Periodically inspect the outer envelope. Replace any lamps that
show scratches,cracks or damage.
8.If a lamp bulb support is used, be sure to insulate the support
electrically to avoid possible decomposition of the bulb glass.
9. Protect lamp base,socket and wiring against moisture, corrosive
atmospheres and excessive heat.
10.Time should be allowed for lamps to stabilize in color when
turned on for the first time.This may require several hours of
operation, with more than one start. Lamp color is also subject
to change under conditions of excess vibration or shock and
color appearance may vary between individual lamps.
11.Lamps may require 4 to 8 minutes to re-light if there is a
power interruption.
12.Take care in handling and disposing of lamps.If an arc tube is
broken,avoid skin contact with any of the contents or fragments.
1) Measured at 100 hrs.life.Approximate lumen values listed are for vertical operation of the lamp.
2)Approximate lumen output at 40% of lamp rated average life.
3) Measured at rated lamp watts on a linear reactor.LPW does not include ballast losses.
4) Measured with the lamp operating at rated watts.
5) Option-PulseWidth @ 90% Peak, 1 micro second minimum with 2 pulses per half cycle.
6) Rated average life is the life obtained,on the average, from large representative groups of lamps in laboratory tests
under controlled conditions at 10 or more operating hours per start.It is based on survival of at least 50% of the
lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
Above specifications subject to change without notice.
Electrical and Technical Data
L
amp OperatingVoltage (rms)(Nominal)
3
–85 (39W)
––––––––––––––––––––––––––––––––––88 (70W)
Initial LampVoltage Range (rms)
4
––––––77-93 (39W)
–––––––––––––––––––––––––––––––––83-93 (70W)
Lamp Operating
Current (Amps) Nominal (rms) ––––––––0.46 (39W)
–––––––––––––––––––––––––––––––––0.83 (70W)
Lamp Current Crest Factor (Maximum)–––––––––1.8
W
arm-up to 80% Full Brightness –––––––––3 minutes
RestrikeTime for Hot Lamps ––––––––– 4–8 minutes
B
allast Open CircuitVoltage ––––209 RMS Min.(39W)
––––––––––––––––––––––––––198 RMS Min.(70W)
P
ulse PeakVolts––––––––––––––––––––––3000-4000
P
ulseWidth @ 90% Peak–––––2 Micro Sec. Minimum
P
ulse Repetition Rate (Minimum)
5
––1 per Half Cycle
M
inimum OperatingTemp.––––––––––– -30˚C (-22˚F)
Physical Characteristics
B
ulb Size –––––––––––––––––––––––––––––––––T-4
B
ulb Finish ––––––––––––––––––––––––––––––Clear
B
ase––––––––––––––––––––––––––––––G-8.5 Bi-Pin
M
ax.Overall Length (MOL) ––––––––––3.35'' (85mm)
L
ight Center Length (LCL)––––––––––––2.0'' (52mm)
A
rc Length––––––––––––––––––––0.2'' (5mm)(39W)
––––––––––––––––––––––––––––0.28" (7mm)(70W)
ArcTube Material ––––––––––PolycrystallineAlumina
Max.Permissible BulbTemp.––––500ºC (932ºF)(39W)
–––––––––––––––––––––––––550˚C (1022˚F)(70W)
M
ax.Permissible PinchTemp. ––––––––300ºC (572ºF)
Max.ArcTube to Base Eccentricity––––––––––––––3º
Operating Characteristics
RatedAverage Life,Hours.
6
––––––––––––––––12,000
Correlated ColorTemp.(CCT)
2
––––––––––––4200K
CIE ChromaticityApprox.
2
–––––x-.370,y-.365 (39W)
––––––––––––––––––––––––––x-.364 y-.360 (70W)
Efficacy (lpw)–––––––––––––––––––––––––––––––85
Operating Position
Universal-Enclosed Luminaires Only
Note: Use on thermally protected
electronic
ballast only.
© 2008 Philips Lighting Company.All rights reserved.
Printed in USA 12/08
P-5892-A
www.philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O.Box 6800
Somerset,NJ 08875-6800
1-800-555-0050
A Division of PhilipsElectronics NorthAmerica Corporation
Philips Lighting
281 Hillmount Road
Markham,Ontario
Canada L6C 2S3
1-800-555-0050
A Division ofPhilips Electronics Ltd.
Representative Spectral Power Distribution
of MasterColor® 4000K Lamps
100
80
60
4
0
20
0
4
00 450 500 550 600 650 700
Relative Energy
Wavelength (Nanometers)