Philips 3000K Indoor Furnishings User Manual


 
CDM Elite/T6
Philips MasterColor
®
Elite Ceramic Metal Halide 3000K Tubular
Single-Ended T6 Lamps
Ordering Data
ANSI Approx. Approx.
Product Pkg. Nom. Ballast Initial Mean
Number Ordering Code Qty. Watt. Code Lumens
1
Lumens
2
CRI
40483-0 CDM Elite35/T6/930 12 39 C130/E 3500 3150 90
14836-1 CDM Elite70/T6/930 12 70 C139/E 7300 6500 90
WARNINGS,CAUTIONSAND OPERATING
INSTRUCTIONS for MasterColor
®
Ceramic Metal
Halide Lamps:Single-Ended CDM-T G12 and CDM-TC G8.5
(Universal);except CDM EliteTC/35/930 and CDM Elite
T6/35/930 (Vertical Position ± 60
˚);
Double-Ended
CDM-TD RX7 (Horizontal ± 45º,Enclosed Fixtures Only)
R
“WARNING:These lamps can cause serious skin burn and
eye inflammation from short wave ultraviolet radiation if outer
envelope of the lamp is broken or punctured.Do not use where
people will remain for more than a few minutes unless adequate
shielding or other safety precautions are used. Certain lamps that
will automatically extinguish when the outer envelope is broken or
punctured are commercially available.”This lamp complies with FDA
radiation performance standard 21 CFR subchapter J. (USA:21CFR
1040.30 Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured,turn off at once
and replace the lamp to avoid possible injury from
hazardous short wave ultraviolet radiation.Do not scratch
the outer bulb or subject it to pressure as this could cause
the outer bulb to crack or shatter.A partial vacuum in the
outer bulb may cause glass to fly if the envelope is struck.
WARNING:The arc-tube of metal halide lamps are designed to
operate under high pressure and at temperatures up to 1000º C and
can unexpectedly rupture due to internal or external factors such as
a ballast failure or misapplication If the arc-tube ruptures for any
reason,the outer bulb may break and pieces of extremely hot glass
might be discharged into the surrounding environment.If such
a
rupture were to happen,THERE ISA RISK OF PERSONAL
INJURY,PROPERTY DAMAGE,BURNSAND FIRE.
Certain lamps that will retain all the glass particles should
inner arc-tube rupture occur are commercially available
from Philips Lighting Company.
RELAMP FIXTURESATOR BEFORETHE END OF
RATED LIFE.Allowing lamps to operate until they fail is
not advised and may increase the possibility of inner arc
tube rupture.
This lamp contains an arc tube with a filling gas containing
less than10 nCi of Kr-85 and is distributedby PhilipsLighting
Company,a division of Philips Electronics NorthAmerica
Corporation,Somerset,New Jersey,08875.
CAUTION:TO REDUCETHE RISK OF PERSONAL INJURY,
PROPERTY DAMAGE,BURNSAND FIRE RESULTING FROM
ANARC-TUBE RUPTURETHE FOLLOWING LAMP
OPERATING INSTRUCTIONS MUST BE FOLLOWED:
LAMP OPERATING INSTRUCTIONS:
1.RELAMP FIXTURESAT OR BEFORETHE END OF RATED LIFE.
Allowing lamps to operate until they fail is not advised and may
increase the possibility of inner arc tube rupture.
2.Use only in fully enclosed fixtures capable of withstanding particles
of glass having temperatures up to 1000ºC.Lens/diffuser material
must be heat resistant.Consult fixture manufacturer regarding the
suitability of the fixture for this lamp.
3.Do not operate a fixture with a missing or broken lens/diffuser.
4.Operate lamp only within specified limits of operating position.
5.Before lamp installation/replacement,shut power off and allow
lamp and fixture to cool to avoid electrical shock and potential
burn hazards.
6.Use only auxiliary equipment meeting Philips and/orANSI standards.
Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B.Fortotal supplyload referto ballast manufacturers electricaldata.
C.Operate CDM-T6 (G12 base) lamps only onthermally
protected ballasts.
D.Operate CDM-TC lamps (G8.5 base),CDM-T6 Elite
lamps,and CDM-T639W/842lamps onlyon thermally
protected electronic
ballasts.
7.Periodically inspect the outer envelope.Replace any lamps that
show scratches,cracks or damage.
8.If a lamp bulb support is used,be sure to insulate the support
electrically to avoid possible decomposition of the bulb glass.
9.Protect lamp base,socket and wiring against moisture,corrosive
atmospheres and excessive heat.
10.Time should be allowed for lamps to stabilize in color when
turned on for the first time.This may require several hours of
operation,with more than one start.Lamp color is also subject to
change under conditions of excess vibration or shock and color
appearance may vary between individual lamps.
11.Lamps may require 4 to 8 minutes to re-light if there is a
power interruption.
12.Take care in handling and disposing of lamps.If an arc tube is
broken,avoid skin contact with any of the contents orfragments.
1) Measured at 100 hrs.life.Approximate lumen values listed are for vertical operation of the lamp.
2)Approximate lumen output at 40% of lamp rated average life.
3) Measured at rated lamp watts on a linear reactor.LPW does not include ballast losses.
4) Measured with the lamp operating at rated watts.
5) Option-PulseWidth @ 90% Peak,1 micro second minimum with 2 pulses per half cycle.
6) Rated average life is the life obtained,on the average,from large representative groups of lamps in laboratory tests
under controlled conditions at 10 or more operating hours per start.It is based on survival of at least 50% of the
lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
Footnotes from front page:
* Based on a MasterColor Elite 3000KTubular Single-EndedT6 70W lamp with 7,300 initial lumens
vs.a CDMT6 70W lamp with 6,600 initial lumens.
** Based on a MasterColor Elite 3000KTubular Single-EndedT6 70W lamp with 6,500 design lumens
vs.a CDMT6 70W lamp with 4,950 design lumens.
Electrical and Technical Data
Lamp OperatingVolt.(rms)(Nom.)
3
–––––––85 (39W)
–––––––––––––––––––––––––––––––––––86 (70W)
Initial LampVolt.Range (rms)
4
––––––––––––––80-100
Lamp Operating
Current (Amps) Nominal (rms) ––––––––0.53 (39W)
––––––––––––––––––––––––––––––––––0.98 (70W)
Lamp Current Crest Factor (Maximum)–––––––––1.8
Warm-up to 80% Full Brightness –––––––––2 minutes
RestrikeTime for Hot Lamps–––––––––– 4-8 minutes
Ballast Open CircuitVoltage––––209 RMS Min.(39W)
––––––––––––––––––––––––––198 RMS Min.(70W)
Pulse PeakVolts––––––––––––––––––––––3000-4000
PulseWidth @ 90% Peak–––––2 Micro Sec.Minimum
Pulse Repetition Rate (Minimum)
5
–––2 per Half Cycle
Minimum OperatingTemp.––––––––––– -30˚C (-22˚F)
Physical Characteristics
Bulb Size –––––––––––––––––––––––––––––––––T-6
Bulb Finish ––––––––––––––––––––––––––––––Clear
Base ––––––––––––––––––––––––––––––G-12 Bi-Pin
Max.Overall Length (MOL) –––––––––––––––––3
15
16"
Light Center Length (LCL) ––––––––––––––––––2
7
32''
Arc Length –––––––––––––––––0.17" (4.3mm)(39W)
–––––––––––––––––––––––––0.23'' (5.75mm)(70W)
Max.BulbTemp. –––––––––––––––––– 500˚C (932˚F)
Max.BaseTemp.–––––––––––––––––––250˚C (482˚F)
ArcTube Material –––––––––Poly CrystallineAlumina
Max Bulb to Base Eccentricity –––––––––––––––––3˚
Max.ArcTube to Base Eccentricity––––––––––––––3˚
Operating Characteristics
RatedAverage Life,Hours.
6
––––––––––––––––12,000
Correlated ColorTemp.(CCT)
2
––––––––––––3000K
CIE ChromaticityApprox.
2
–––––x-.432 y-.396 (39W)
–––––––––––––––––––––––––––x-.434 y-.395 (70W)
–––––––––––––––––––––––––––––––––––––––––––
Efficacy (lpw)–––––––––––––––––––––––––90 (39W)
––––––––––––––––––––––––––––––––––104 (70W)
Operating Position
Vertical position ± 60˚(39W);Universal (70W)
Enclosed luminaires only.
NOTE: Use on thermally protected
electronic
ballast only.
Above specifications subject to change without notice.
100
8
0
60
40
20
0
400 450 500 550 600 650 700
Relative Energy
Wavelength—nanometers
R
epresentative Spectral Power
Distribution of MasterColor
®
3000K Lamps
Printed on chlorine free paper from Sappi Fine Paper mills,who are accredited with EMAS environmental certification.
Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.
© 2007 Philips Lighting Company.All rights reserved.
Printed in USA 1/08
P-5900-A
www.philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O.Box 6800
Somerset,NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham,Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
P-5900 CMH Elite T6 Product Bulletin.qxd:product bulletin 1/29/08 6:22 PM Page 2