Petsafe PIG00-10777 Pet Fence User Manual


 
24 1-800-732-2677
System Test
The system test is used to determine the cause of system problems that have not been addressed elsewhere in this guide.
You will need a 10 foot piece of Boundary Wire with
3
8
inch of insulation removed from each end to use as a test loop wire.
Follow the steps below to perform the system test:
1. Remove the Receiver Collar from your dog and make sure it is installed with a good battery.
2. Unplug the Power Adapter from the Fence Transmitter Power Jack.
3. Set the Boundary Control switch to B.
4. Set the Receiver Collar Static Correction Level to 5.
5. Disconnect the twisted Boundary Wire from the Boundary Wire terminals on the Fence Transmitter by pressing the red
release levers on the connector and pulling the wires free.
6. Insert the two ends of the test loop wire into the Boundary Wire Terminals on the Transmitter.
7. Plug the Power Adapter into Fence Transmitter Power Jack.
8. Note the original position of the Boundary Width Control knob and turn the Boundary Width control knob to 10 and
then back to 5.
9. Place the Test Light Tool Contacts on the Contact Points of the Receiver Collar. While holding the Receiver Collar with
the Test Light Tool in place, start outside of the test loop and walk toward the loop. Make a mental note of the distance
between you and the wire when the Receiver Collar activates.
10. Turn the Boundary Width Control knob to 10 and repeat Step 9. The distance where the Receiver Collar activates should
be greater than that of Step 9.
11. If more than one Receiver Collar is used on the system, repeat the above test on each collar.
12. Interpreting the Results:
a. If the Power light or the Loop indicator light are not both lit on the Fence Transmitter, or the alarm is on, there is a
problem with the Transmitter. Contact the Customer Care Center.
b. If both the Power and Loop indicator lights are on, but the Receiver Collar does not activate on the test loop wire,
the Receiver Collar is not working. Contact the Customer Care Center.
c. If both the Power and Loop indicator lights are on and the Receiver Collar is activating at different distances on the
test loop wire, the problem is in the containment Boundary Wire. Perform the Wire Break Location Test.
13. When testing is complete, return the Boundary Control Switch and the Boundary Width Control setting to their original
position.
14. Repeat the Boundary Width testing from Step 6 on Page 12 until you achieve the desired Boundary Width between 12
to 20 feet.