P/N 472299 6 Rev. B 1-20-04
Figure 6.
J1
DDTC
WATER PRESSURE
SWITCH
MiniMax NT TSI w/DDTC WIRING DIAGRAM
GY
AIR PRESSURE SW.
O
BLOWER
O
J5 J6J8
G
COM
NO
R/W
R
BK/W
BK
O
REMOTE CONTROL
MANUAL FOR
& INSTALLATION
SEE OPERATION
150˚F
W
HIGH LIMITS
O
115˚F
R
R
BL
JI0
TFUSE/HLMT/PRESS
J4
24V
J2
J7
J9
P9
J11
BK
W
BL
GY
O
R
BL
Y
O
W
W
W
IF ORIGINAL FACTORY WIRING MUST BE REPLACED,
INSTALLER MUST SUPPLY UL/CSA APPROVED WIRE
WITH 18 AWG, 600V, 105˚ C TEMP. RATING.
THERMAL FUSE WIRING MUST BE REPLACED WITH
18 AWG, 600V, 150˚ C TEMP. RATING.
BK
Y
BLOWER
R
W
BL
PI0P4 P7
W
GY
O
W
BL
P11
O
W
R
THERMAL FUSE
W
W
BR
HOT SURFACE
IGNITER
W
MV
W
BK
FLAME SENSOR
PR O
PR
O
FOR 240 VAC
CON-FEM(BR)
Y
O
BK
GAS VALVE
MV
BK/W
G
W
PR
R/W
R
CON-MAL(W)
Y
BK
BL
BK
W
W
BK
FOR 120 VAC
CON-FEM(BL)
BOND LOG
W
W
(ON THE SIDE JACKET)
WIRE COLOR CODE
BK : BLACK
BL : BLUE
BR : BROWN
R : RED
O : ORANGE
Y : YELLOW
G : GREEN
GY : GRAY
PR : PURPLE
W : WHITE
R/W : RED W/WHITE TRACE
BK/W : BLACK W/WHITE TRACE
Y
BK
5
W
WIRE HERE
ATTACH
GROUND
G
TERM
BLOCK
N
L
BLOCK
4
3
BK
BK
2
1
W
BK
W
G
TERM
B
240 VAC
120 VAC
BK
W
G
OR
A
24VAC
SPA
COM
POOL
{
VLV
FAN
THERMISTER
IGN MOD
VALGNDPS THFS
IGN/
240
L1
IGN/
120
+
-
FC
24
VAC
F1 F2