Pentair 4/100 Water Pump User Manual


 
13
IntelliFlo 4 Installation and User’s Guide
Connecting IntelliFlo 4 to an IntelliTouch System
The IntelliFlo 4 can be controlled by an IntelliTouch system via the RS-485 communication cable
(P/N 350122). In this configuration, IntelliTouch 4 starts, stops and controls the speed of the IntelliFlo 4
pump. When the IntelliTouch does this, it rewrites the IntelliFlo 4 memory, which can take several seconds.
This causes a delay after a command is given on the IntelliTouch control panel until the Intelliflo 4 physically
responds.
The IntelliFlo 4 control panel is disabled when communicating with the IntelliTouch system. Note that
IntelliTouch will not start communicating with the IntelliFlo 4 until the appropriate pump address is assigned
to a circuit. The IntelliFlo 4 default pump address is one. See page 6 for details about how to check the
address and change if necessary. For more information, refer to the IntelliTouch User's Guide (P/N
520102).
To connect the IntelliFlo 4 communication cable to IntelliTouch load center:
1. CAUTION - Switch the main power off to the IntelliTouch load center.
2. Unlatch the IntelliTouch load center front door spring latches, and open the front door.
3. Remove the cover-panel screws securing the high voltage cover-panel, and remove it from the
enclosure.
4. Loosen the two control panel access screws and fold down the outdoor control panel.
5. Insert the two-wire cable into plastic grommet on the bottom of the enclosure and route the wire up
through the low voltage raceway to the Personality board.
IntelliTouch Load Center
Cover-panel
screw
(Cover-panel not
shown)
Access
screw
Personality Board
Low voltage raceway
Plastic grommet