INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN
FOR PELLA
®
PRECISION FIT
®
, CASEMENT, RENOVATION POCKET
REPLACEMENT AND FIXED WINDOW REPLACEMENT
Part Number: 816G0101
© 2010 Pella Corporation
Lea las instrucciones en español en el reverso.
REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT.
YOU WILL NEED TO SUPPLY: TOOLS REQUIRED:
• Cedar or Impervious shims/spacers (12 to 20)
• Wood blocking and bracing
• Closed cell foam backer rod/sealant backer (12 to 30 ft.)
• Pella® SmartFlash™ foil backed butyl window
and door ashing tape or equivalent
• High quality exterior grade polyurethane or silicone sealant
(1 tube per window)
• Great Stu ™ Window and Door Insulating Foam Sealant
by the Dow Chemical Company or equivalent low pressure
polyurethane window and door foam -
DO NOT use high pressure or latex foams
• Tape measure
• Level
• Square
• Hammer
• Utility knife
• Sealant gun
• Screwdrivers
(#2 Phillips and Flat blade)
• Rotary cutting tool w/ cut-o wheel (if
existing window has press t pulleys)
• Drill
• Pliers
• Putty Knife
• Pry bar
• T-25 TORX® Driver
• Chisel
SEA
LANT
SEA
LAN
T
Installation will require two or more
persons for safety reasons.
Important! e Pella Precision Fit Casement Replacement Window is designed to replace older style
double-hung windows. e original window frame will remain in place and only the existing sash
will be removed. e Pella Precision Fit Casement Fixed Window is a companion to the Precision Fit
Casement and is designed to replace the xed center window that shares a common stool and sloped
sill with the adjacent windows and has removable interior stops. is application is typically found
in older homes. e original window frame will remain in place and only the existing sash, glass and
existing stops must be removed. ese instructions are not to be used with any other construction
methods. Read these instructions thoroughly before beginning. Failure to install as recommended will
void any warranty, express or implied. For types of installation other than shown, contact your local
Pella representative or visit http://www.pella.com. Building designs, construction methods, building
materials and site conditions unique to your project may require an installation method dierent
from these instructions and additional care. Determining the appropriate installation method is the
responsibility of you, your architect or construction professional.
CAUTION: Many windows in older homes are painted with lead-based paint. Removal of old
windows may disturb this paint. Proper precautions must be taken to minimize exposure to dust
and debris. Consult state or local authorities for more information.
Always read the Pella Limited Warranty before purchasing or installing Pella products.
By installing this product, you are acknowledging that this Limited Warranty is part of the terms of
the sale. Failure to comply with all Pella installation and maintenance instructions may void your Pella
product warranty. See Limited Warranty for complete details at http://warranty.pella.com.