Carbon Tank Wash
!IMPORTANT!
Do not perform the Carbon Tank Wash until the Carbon Tank Soak process is complete.
Notice:
Water will flow out of the downflow inlet side of the Bypass Valve during this process. Be sure you perform
this series of steps in a location suitable for water flow.
Figure 4
1. Reattach the garden hose to the Hose Bib Assembly.
2. Slowly turn on the water 1/4 turn for this entire process.
3. Run water through the upflow inlet side of the Bypass Valve for 15-30 minutes or until the water
discharging from the downflow inlet side of the Bypass Valve runs clear.
4. Turn off the water.
5. Remove the Hose Bib Assembly from the upflow inlet side and attach it to the downflow inlet side
of the Bypass Valve.
6. Run the water through the downflow inlet side for 1 minute or until water runs clear.
7. Turn off the water.
8. Remove the Hose Bib Assembly from the Bypass Valve and disconnect the garden hose.
Note: Please save the Hose Bib Assembly as this will be used in the future for the carbon
exchange.
UPFLOW
INLET
DOWNFLOW
INLET
Water
Bypass Valve
Whole House Water Filter
Garden
Hose
Hose Bib
Assembly