Pelco CX9504 Home Security System User Manual


 
14 Pelco Manual C505M-B (4/97)
7.0 SPECIFICATIONS
ELECTRICAL
Input Voltage (50/60 Hz):
Standard
Version 24, 120, 230 VAC
VS Version 120, 230 VAC
Power Consumption (excluding PTZ):
Standard
Version 6 watts
VS version 6 watts
P/T Output Voltages:
Standard
Version 24, 120, 230 VAC
VS Version 12 VDC PWM at 15 KHz
P/T Output Currents:
Standard
Version 1.5 amps per motor
VS version 3 amps per motor
P/T Output Power:
Standard
Version 50 watts
VS version 35 watts
Camera Output Voltages:
All Versions 24, 120, 230 VAC
Lens Output Voltages:
All Versions 0 to 12 VDC
Control Method:
CX9500 Coaxitron VIS
CX9504 4-wire RS-485
Standard Baud Rates:
CX9500 1 MHz
CX9504 2400 baud
Command Error Rates:
Duplex 0%
Simplex 0.02%
Input Video Level:
All versions 0.5 to 1.5 V p-p
Input Video Format:
Standard NTSC, RS-170
Optional PAL
Video Bandwidth:
All versions 10 MHz
Operating Distances:
Coaxitron
Version 2,000 ft (610 m) on RG-11
RS-485 Version 4,000 ft (1,219 m) on 24 Awg-TP
NOTE:
All standard baud rates from
600 to 19.2K are available on an op-
tional basis. Please consult the fac-
tory.
NOTE:
Operating distances given
here are calculated, and based on
typical performance. The actual cal-
culations are explained in the Instal-
lation section of this manual, and
should be done for each application
prior to installation.