012-05563D Type K Temperature Sensor
®
mometer reading reaches a peak, enter the reading in
the “Standard Value” box for Calibration Point 2, then
click the “Read From Sensor” button for Calibration
Point 2. Cilck “OK” at the bottom of the calibratiion
screen and close the Experiment Setup window.
You can save your calibration as a DataStudio docu-
ment by selecting “Save As…” from the File menu.
Calibrating the Sensor Using Science Workshop
Start the Science Workshop program. Click-and-drag
the analog sensor plug icon to Analog Channel A. Se-
lect “Temperature Sensor (Type-K)” from the list of
analog sensors.
Calibration Point #1: Place the sensor and thermom-
eter in the ice water. In the Experiment Setup window,
double-click on the Type-K sensor icon to open the
Analog Sensor Setup dialog box.
The dialog box will show the “Current Value” of the
voltage produced by the Type-K sensor. When the
voltage value is almost zero, click on the bottom
“Take Reading” button. Enter the thermometer read-
ing in the box labeled “Low Value:”.
Calibration Point #2: Place the sensor and thermom-
eter in the boiling water. The “Current Value” will
show the new voltage produced by the sensor. When
the voltage value reaches a peak, click on the top
“Take Reading” button. Enter the thermometer read-
ing in the box labeled “High Value:”.
You can save your calibration as a Science Workshop
document by selecting “Save As…” from the File
menu.
Limited Warranty
PASCO scientific warrants this product to be free from
defects in materials and workmanship for a period of
one year from the date of shipment to the customer.
PASCO will repair or replace, at its option, any part of
the product which is deemed to be defective in mate-
rial or workmanship. This warranty does not cover
damage to the product caused by abuse or improper
use. Determination of whether a product failure is the
result of a manufacturing defect or improper use by
the customer shall be made solely by PASCO scien-
tific. Responsibility for the return of equipment for
warranty repair belongs to the customer. Equipment
must be properly packed to prevent damage and
shipped postage or freight prepaid. (Damage caused
by improper packing of the equipment for return ship-
ment will not be covered by the warranty.) Shipping
costs for returning the equipment, after repair, will be
paid by PASCO scientific.
Equipment Return
Should this product have to be returned to PASCO
scientific, for whatever reason, notify PASCO scien-
tific by letter or phone BEFORE returning the product.
Upon notification, the return authorization and ship-
ping instructions will be promptly issued.
NOTE: NO EQUIPMENT WILL BE
ACCEPTED FOR RETURN WITHOUT AN
AUTHORIZATION.
When returning equipment for repair, the units must
be packed properly. Carriers will not accept responsi-
bility for damage caused by improper packing. To be
certain the unit will not be damaged in shipment, ob-
serve the following rules:
The carton must be strong enough for the item
shipped.
Make certain there is at least two inches of packing
material between any point on the apparatus and
the inside walls of the carton.
Make certain that the packing material can not shift
in the box, or become compressed, thus letting the
instrument come in contact with the edge of the
box.
P1
1
2
3
4
5
6
7
8
S
8
S
7
3
5
2
4
1
6
YEL +
RED -
2
1
TEMPERATURE
CI-6526
SENSOR
TYPE K
THERMOCOUPLE
PROBE
8-PIN DIN PLUG
PINS FACING YOU
CHROMEL
ALUMEL
Schematic Diagram