Paragon W18 Furnace User Manual


 
19
SETTING THE ALARM DURING FIRING
After you shut off the alarm during firing, you can set it to go off again later at either a higher temperature or
a cool-down temperature.
1) While the furnace is firing, press 7 on the key board.
2) Enter the new temperature.
3) Press ENTER and the furnace will continue firing.
POWER FAILURES
After a brief power failure during firing, [ PF ] will display, alternating with the temperature. Even though it
displays [ PF ], the furnace will continue to fire normally. The display shows [ PF ] simply to notify you of a
brief power failure. Press any key except STOP and normal temperature display will return.
[ ErrP ] appears after an extended power failure. In addition, after an extended power failure the controller
will sound a steady alarm.
When [ ErrP ] appears on the display, press ENTER. The hours fired and furnace temperature reached at the
time of the power failure will be displayed. Then [ ldLE ] will display.
See the “TROUBLE-SHOOTING section of your instructions for causes.
STEAM WAX ELIMINATION
We highly recommend that STEAM WAX ELIMINATION be used prior to a burnout in your furnace. This will
remove 90% of all waxes that melt at 200
°
°°
°
F or less and eliminates several things. First, it eliminates carbon
build-up on the elements of your furnace, giving it a longer life. Second, it eliminates noxious fumes and
odors, especially from closed-in areas. There are 3 sizes of Steam Wax Eliminators available. Ask your dealer
for more information.