Paradox Hellas S.A. DGP2-641RB Door User Manual


 
8 EVO96
4.9 Auto-Arming
If enabled by your installer, you can set the time that an area will arm itself automatically.
4.9.1 Timed Auto-Arming
Your installer can set Timed Auto-Arming to function in either Force or Stay arming
mode. A sixty-second (default value) Exit Delay sequence will begin prior to your
system automatically arming itself at the programmed time.
To set the Auto-Arming timer:
1. Enter your [
ACCESS CODE].
2. Press the [0] button.
3. Press the [
MEM] button or the [] key.
4. If you have access to more than one area, press the area’s
number, or use the
[S] and [T] buttons and press the [
ACC] button when the area you want to
program appears on the screen.
5. Enter the time you want the area to be armed according to the 24-hour clock
(i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00).
6. Press the [
ENTER] button to save and exit.
If you are using the DGP2-648BL keypad, The
MEM action light will flash if a
time is not already programmed. The
PRG action light, the area light of the
chosen area, and the first number of the previous time set will illuminate (
10
light = zero).
4.9.2 No Movement Auto-Arming
Your system can be programmed to send a report to your monitoring station and/or
arm the system if there is no activity in the area during a specified period of time.
Your installer can set No Movement Auto-Arming to function in either Regular or
Stay arming mode.
LCD ICON LED