6. Refer to wiring diagram (Page.5)
Follow all the local electrical safety codes. As well as
the National Electrical Code (NEC).
Using UL approved wire nuts, connect house power
wires to ventilating fan wires (Fig.6):
Black to black; white to white; green to green.
Make sure all connections are fastened firmly after
wiring is finished.
Replace the junction box plate, and then replace
lighting cord to hook. (Fig.5)
Fig.10
Fig.9
Fig.8
Fig.5
8. Finish ceiling work. Ceiling hole should be aligned
with the edge of the flange. (Fig.8)
(Fig.10)
INSTALLATION (JOIST MOUNTING- ) CONTINUED
7. Install the circular duct (4 inches) to the adaptor and
secure it with duct tape or clamps. (Fig.7)
Fig.7
Circular duct
Conduit
Correct
Incorrect
9. Install the fluorescent lamps and then install the
night lamp. (Fig.8)
Fluorescent lamp
12 5
/8 (319)
17 3/8 (441)
Screw driver
Fig.6
Junction box plate
Black to black
White to white
White to white
Black to black
Black to black
White to white
Black to black
Junction box
Green to green
Wire nut
Fan body
Joist
4 Long screws (ST4.2X20)
Slot
Mounting spring
Grille
Switch
labels
Switch
labels
For Model FV-11VHL2 For Model FV-11VH2
Note:Do not mount grille and springs conversely. If
the grille is mounted in the opposite direction,
the grille can not be fitted to the ceiling, so
then reverse the grille position and try to
mount again.
10. Insert mounting springs into slots as shown and
mount grille to fan body. (Fig.9)
Duct tape
or clamps
Screw
Junction box
plate
5. Remove the lighting cord out from hook (FV-11VHL2),
then remove junction box plate and secure conduit or
stress relief to wiring box knock-out hole.(Fig.5)
Lighting cord
Hook
Conduit
Night lamp