Panasonic CZ-18BT1U + CU-KS18NKU Air Conditioner User Manual


 
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit CS-KS12NB41 & CZ-18BT1U
Outdoor Unit
CU-KS12NK1A
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor + Compressor
Performance at 115V Single-phase 60Hz
Rating conditions Running amp. 0.21
Power input 18
12.39
1,242
Cooling
12.6
1,260
Rating conditions: Indoor air temperature: 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB
Outdoor air temperature: 95 °F (35 °C) DB
A
W
34