Panasonic CZ-18BT1U Air Conditioner User Manual


 
11
Fig. 6-23
Fig. 6-24 Fig. 6-25
fit into the holes in the ceiling panel.
Place the corner cover so that the 3 tabs
Then fasten it in place with the supplied screws.
Pin
Hole for ceiling
panel hook
the grille from
dropping
Hook that prevents
Can be installed rotated 90
* The grille can be installed
with these hinges facing
in any of 4 directions.
3-6-4. How to Attach the Corner Cover and Air-Intake Grille
3-6-3. Wiring the Ceiling Panel and the Indicator
(1) Remove the 2 screws from the control box cover, then open
the cover. Be careful that the cover does not fall.
 &RQQHFWWKH3 )/$3 ZLULQJFRQQHFWRUIURPWKHFHLOLQJ
panel to the connector on the control PCB in the control box.
(Fig. 6-21)
(3) Connect the 7P IND and 4P RC wiring connector from the
indicator to the connectors on the control PCB in the control
box. (Fig. 6-21)
(4) Be sure to use the clamps to fasten the connector wires in
place. (Fig. 6-21)
(5) Tighten the 2 cover screws to
close the cover.
Check that the wiring
connectors are not caught
between the electrical
component box and the cover.
If the indicator connector is
not securely connected,
the remote controller
signal will not be
received.
If the connectors are not
connected, the auto flap will not
operate. Be sure
to connect them securely.
A. Attaching the corner cover
(1) Check that the safety strap from the corner cover is fas-
tened to the ceiling panel pin, as shown in the figure.
(Fig. 6-23)
(2) Use the supplied screws to attach the corner cover to the
ceiling panel.
B. Attaching the air-intake grille
To install the air-intake grille, follow the steps for 3-6-1.
Before Installing the Ceiling Panel in the reverse order.
By rotating the air-intake grille, it is possible to attach the
grille onto the ceiling panel
from any of 4 directions.
(Fig. 6-25)
When attaching the air-intake
grille, be careful that the flap
and the indicator wiring do
not become caught.
Be sure to attach the safety
cord that prevents the air-intake
grille from dropping off to the
ceiling panel unit as shown
in Fig. 6-24.
)/$3
RCIND
Indicator
Indicator
7P IND and 4P RC wiring connector
7P IND and 4P RC
Ceiling panel
3)/$3ZLULQJFRQQHFWRU
Clamps
Control box
Indoor unit
* Pass the wiring connectors through the clamps to fasten them in place,
as shown in the figure.
wiring connector
7P
4P
5P
3)/$3
wiring connector
Control box
As to how to attach the indicator cover, refer to Fig.6-23.
Drain pipe side
Refrigerant tube side
Indicator cover
Power box
Fig. 6-22
Fig. 6-21