Panasonic CW-C83GU Air Conditioner User Manual


 
About 12.7mm (
1
/
2
")
76.2cm (30")~
152.4cm (60")
Awning
Cooled air
Fence
Over 50.8cm (20")
Heat
radiation
55.8cm (22") to
91.44cm (36")
Offset
12.7mm (
1
/
2
") to
31.8mm (1
1
/
4
")
Sill
Exterior
Interior wall
47cm (18
1
/2") min.
(Without frame curtain)
Stool
38cm (15") min
(With frame curtain)
11
INSTALLATION
Features and Installation
1. To prevent vibration and noise, make sure
the unit is installed securely and firmly
2. Install the unit where the sunlight does not
shine directly on the unit.
3. The outside of the cabinet must extend
outward for at least 28cm (11") and there
should be no obstacles, such as a fence or
wall, within 50.8cm (20") from the back of
the cabinet because it will prevent heat
radiation of the condenser.
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the
structure.
4. Install the unit a little slanted so the back is slightly lower than the front
(about 12.7mm (
1
/
2")).
This will force condensed water to flow to the outside.
5. Install the unit with the bottom about 76.2cm (30")~152.4cm (60") above the floor level.
Window Requirements
NOTE: All supporting parts should be secured to firm wood, masonry, or metal.
This unit is designed for installation in
standard double hung windows with actual
opening widths from 55.88cm (22") to
91.44cm (36").
The top and bottom window sash must open
sufficiently to allow a clear vertical opening of
38cm (15") from the bottom of the upper sash
to the window stool.
How to Install the Unit