Panasonic CU-KS30NKUA Air Conditioner User Manual


 
Indoor Unit CS-KS36NKU
Outdoor Unit CU-KS36NKUA
Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (60Hz, 230V)
• Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value.
NOTE
(1) Low pressure performance chart
(2) Operating current performance chart
(3) Indoor discharge air performance chart
-4
(-20)
5
(-15)
14
(-10)
23
(-5)
32
(0)
41
(5)
50
(10)
59
(15)
68
(20)
77
(25)
86
(30)
95
(35)
104
(40)
Outdoor inlet air DB temp. °F(°C)
Outdoor inlet air DB temp. °F(°C)
Outdoor inlet air DB temp. °F(°C)
Operating current (A)
Indoor discharge air temperature °F(°C)
Low pressure at wide tube service valve
psig(MPaG)
-4
(-20)
5
(-15)
14
(-10)
23
(-5)
32
(0)
41
(5)
50
(10)
59
(15)
68
(20)
77
(25)
86
(30)
95
(35)
104
(40)
-4
(-20)
5
(-15)
14
(-10)
23
(-5)
32
(0)
41
(5)
50
(10)
59
(15)
68
(20)
77
(25)
86
(30)
95
(35)
104
(40)
57.2 (14)
60.8 (16)
64.4 (18)
53.6 (12)
50.0 (10)
46.4 (8)
42.8 (6)
10
12
14
16
18
20
22
24
26
28
104
(0.7)
117
(0.8)
131
(0.9)
145
(1.0)
159
(1.1)
174
(1.2)
Hi FanLo fan
Hi FanLo fan
Hi FanLo fan
Indoor Air Temp.86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor Air Temp.86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor Air Temp.86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor Air Temp.86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor Air Temp.86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor Air Temp.86°F (30°C)
80°F (27°C)
75°F (24°C)