Panasonic CU-KE36NKU Air Conditioner User Manual


 
Indoor Unit : CS-KE30NKU
Outdoor Unit : CU-KE30NKU
Power Supply : 230V Single Phase 60Hz
< Heating Capacity >
5-4. Heating Capacity
TH : Total Heating Capacity (BTU/h)
1.
Rating conditions (#)
: Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB
: Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB
2.
3. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air
Prevention Protection during heating operation into account. For this reason, the value may vary
from the actual heating characteristics.
NOTE
RATING CAPACITY: 33,000 BTU/h AIR FLOW RATE: 671 CFM
OUTDOOR INDOOR
ENT. TEMP.
o
F (
o
C) AMBIENT TEMP.
o
F (
o
C)
WB 60 65 70 75 80
(15.6) (18.3) (21.1) (23.9) (26.7)
0 (-17.8) TH 18,060 18,120 18,170 18,210 18,240
CI
1.77 1.85 1.93 2.01 2.09
3 (-16.1) TH 18,670 18,730 18,780 18,820 18,850
CI
1.80 1.88 1.97 2.05 2.14
8 (-13.3) TH 20,120 20,190 20,240 20,280 20,320
CI
1.87 1.96 2.06 2.15 2.24
13 (-10.6) TH 21,640 21,710 21,770 21,810 21,840
CI
1.95 2.05 2.15 2.25 2.35
18 (-7.8) TH 23,320 23,390 23,450 23,500 23,530
CI
2.04 2.15 2.26 2.37 2.47
23 (-5.0) TH 25,100 25,170 25,230 25,280 25,310
CI
2.14 2.26 2.37 2.49 2.61
28 (-2.2) TH 26,960 27,030 27,090 27,140 27,160
CI
2.25 2.37 2.50 2.63 2.75
33 (0.6) TH 28,900 28,970 29,030 29,070 29,090
CI
2.36 2.49 2.63 2.77 2.90
38 (3.3) TH 30,830 30,900 30,950 30,990 30,500
CI
2.48 2.62 2.77 2.91 3.01
43 (6.1) TH 32,880 32,950 # 33,000 33,030 30,830
CI
2.61 2.76 2.92 3.08 3.01
48 (8.9) TH 34,980 35,050 35,090 35,120 31,060
CI
2.75 2.91 3.08 3.25 3.01
53 (11.7) TH 37,120 37,180 37,220 35,450 31,180
CI
3.08 3.26 3.26 3.27 3.01
58 (14.4) TH 39,210 39,260 38,650 35,450 31,180
CI
3.06 3.25 3.44 3.27 3.01
63 (17.2) TH 41,380 41,410 38,650 35,340 31,050
CI
3.24 3.44 3.53 3.27 3.01
65 (18.3) TH 42,230 41,840 38,650 35,250 30,960
CI
3.32 3.53 3.53 3.27 3.01