Panasonic CU-C12CKP5 Air Conditioner User Manual


 
MANUAL
Five stages of adjustment
can be made between
14° ~ 36°.
MANUAL
Five stages of adjustment
can be made between
0° ~ 61°.
Heat Pump Model
MANUAL
Five stages of adjustment
can be made between
14° ~ 36°.
Swing up/down
Automatically
Move up/down
Automatically
MANUAL
Five stages of adjustment
can be made between
0° ~ 61°.
When the discharge air
temperature is low such
as at the start of heating
operation, the air blows
at horizontal level. As
the temperature rises,
the hot air blows at a
downward direction.
To stop this operation,
press MANUAL.
HEAT Operation
AUTO
COOL / DRY Operation
AUTO
Swing up/down
Automatically
Operation Details
COOL Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low fan speed.
HEAT Heating Operation
(for Heat Pump Model only)
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN Air Circulation Operation
(for Cooling Model only)
When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
2°C below the set temperature.
(It is useful when using a heater).
Setting the Fan Speed
Press 4 to select:-
FAN Low Fan Speed
FAN Medium Fan Speed
FAN High Fan Speed
AUTO
FAN Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
Setting the Vertical Airflow Direction
Press 5 or 6 to select:-
Cooling Model
Setting the Horizontal Airflow Direction
Use this air conditioner under the following
conditions:
Cooling Model
Adjust it manually
Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
Heat Pump Model
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature
Minimum Temperature
WBT
23
11
DBT
43
16
WBT
26
11
Indoor Outdoor
Unit in °C
DBT
32
16
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature-Cooling
(Maximum Temperature-Heating)
Minimum Temperature-Cooling
(Minimum Temperature-Heating)
DBT
32
(30)
16
(16)
WBT
23
(-)
11
(-)
DBT
43
(24)
16
(-5)
WBT
26
(18)
11
(-6)
Indoor
Outdoor
Unit in °C
36°
36° 61°
COOL / DRY Operation
AUTO
FAN Operation
AUTO
SETTING THE TIMER
Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.
ON-TIMER Operation
To start the air conditioner operation automatically.
Press 1 to set the operation.
Press 2 to increase or decrease the time.
Then press 3.
To cancel this operation, press 4.
OFF-TIMER Operation
To stop the air conditioner operation automatically.
Press 5 to set the operation.
Press 2 to increase or decrease the time.
Then press 3.
To cancel this operation, press 4.
Timer Mode Operation Details
When the ON-Timer is set, operation will start
before the actual set time. This is to enable the
room temperature reaches the set temperature at
the set time.
Once the ON/OFF Timer is set, operation will start/
stop at the set time everyday.
The current time is not displayed when the timers
are set.
When both timers are used together, the TIMER
mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.
CONVENIENCE OPERATION
Powerful Mode Operation
To obtain the set temperature quickly.
Press 6.
* Powerful mode indicator (orange) on the indoor
unit will light up.
* Powerful mode will operate for 15 minutes only.
To cancel this operation, press once more.
Powerful Mode Operation Details
The changes of the temperature and airflow volume
are automatic.
The remote control display remains unchanged.
If operation mode button is pressed, powerful
operation will be cancelled.
During FAN Air circulation operation, the powerful
operation are not available.
(cooling model only)
Quiet Mode Operation
To provide quiet operation.
Press 7.
* Quiet mode indicator on the indoor unit will light
up.
To cancel this operation, press once more.
Operation Details
Air flow sound will reduce during operation.
Ionizer Mode Operation
Produce negative ion for fresh air.
Press 8.
* Ion mode indicator on the indoor unit will light up.
To cancel this operation, press once more.
Operation Details
Air conditioner ON:
Provide negative ion during operation.
Air conditioner OFF:
Provide negative ion with FAN operation.
If blinking, press 8 twice.
If still blinking, please call service.
CHECK
AUTO
AUTOHEAT DRYFANCOOL
FAN
AUTO
RESET CLOCK
MODE
POWERFUL
QUIET
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
OFF/ON
AUTO
MANUAL
3
6
4
1
7
5
2
8
Airflow
volume
Super High
Automatic
Powerful Mode
Operation
COOL / DRY
HEAT
(for Heat Pump
model only)
Temperature
3°C lower
than set temp.
3°C higher
than set temp.
Heat Pump Model
COOL,DRY, >15 minutes
in advance
HEAT, AUTO>30 minutes
in advance
Cooling Model
COOL,DRY, >15 minutes
AUTO in advance
34
CS-C7CKP CU-C7CKP5 / CS-C9CKP CU-C9CKP5 / CS-C9CKP CU-C9CKP6 / CS-C12CKP CU-C12CKP5 / CS-C12CKP CU-C12CKP6