Panasonic CS-S18NKUA Air Conditioner User Manual


 
23
10.1.3.8 Wire Stripping and connecting requirement
10.1.3.9 Cutting and flaring the piping
1 Please cut using pipe cutter and then remove the burrs.
2 Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end
down to avoid the metal powder entering the pipe.
3 Please make flare after inserting the flare nut onto the copper pipes.