Panasonic CS-KS18B4UW & CZ-18BT1U Air Conditioner User Manual


 
8
(1) Recommended dimensions of the baffle plates
D
E
C
J
H
K
G
B
I
P
Q
A
F
N
(2- 6.5 mm)
2- 1/4"
(2- 6 mm)
2- 15/64"
A
B
H
C
E
F
G
G
M
L
K
I
J
D
(4- 6.5 mm)
4- 1/4"
Fig. 5e
For Air Intake
For Air Discharge
Material to be used: Metal plate with corrosion protection treatment
Plate thickness: 0.0394 to 0.0472" (1.0 to 1.2 mm)
(2) Parts required (locally purchased except for screws)
Dimensions
ABCDEFGH I JKNPQ
Model
CU-KS12NK1A
(inch)
21-21/32
25/32 2-5/32 17-5/16 13 25/64 19/32 23/64 19/64 17-3/8 25/64 5-29/32 25/32 25/32
(mm) 550 20 55 440 330 10 15 9 7.5 441 10 150 20 20
Dimensions
ABCDEFGH I JKLM
Model
CU-KS12NK1A
(inch)
19-3/32 20-3/32
13-25/32
5-29/32
17-17/32
25/32 2-5/32 14-9/16 2-3/4 3-11/32 19/32 1-3/8 1-3/8
(mm) 485 510 350 150 445 20 55 370 70 85 15 35 35
Air Intake Baffle
Air Discharge Baffle
Fig. 5d
Item Q’ty Remarks
Baffle plate 1
Screw 5/32 15/32" (4 12 mm) tapping 2 Attached to outdoor unit
Bolt 15/64 19/32 – 25/32" (M6 15 – 20 mm) 2
Nut 15/64" (M6) 2
Washer 2
Spring washer 2
Item Q’ty Remarks
Baffle plate 1
Bolt 15/64 13/32 – 19/32" (M6 10 – 15 mm) 4
Nut 15/64" (M6) 4
Washer 4
Spring washer 4
Air Intake Baffle
Air Discharge Baffle
CU-KS12NK1A