Sunlight Sensor operation
Set
temperature
COOL/DRY
+1 °C
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
Automatic Voltage Switcher (AVS)
When power supply is unstable, where the AC voltage supplied is below 185 V or above 260 V, AVS will
switch off the outdoor unit to protect the compressor. During this condition, the AVS indicator will turn on.
POWER/AVS
Indicator Indoor unit Outdoor unit
Green ON ON
Orange ON OFF
Note: Room temperature may rise during AVS ON.
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature (°C)
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 23 55 31
Min. 16 11 16 11
The human activity sensor will also scan for area of heat source and movement in a room.
Detection area Human activity indicator
120º
7m
At left area At center / multiple area At right area
The unit judges human activity area for a few seconds before indicator updates. Based on area activeness
horizontal air ow direction louver will adjust either x at predetermined position or swing left/right periodically.
• The human activity sensor performance is in uenced by indoor unit location, movement speed, temperature
range, etc.
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidi er from the sensor’s detection