Panasonic CS-C12CKPG Air Conditioner User Manual


 
ENGLISH
6
Operation Details
COOL Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low fan speed.
HEAT Heating Operation
(for Heat Pump Model only)
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depending on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN Air Circulation Operation
(for Cooling Model only)
When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
4°F below the set temperature.
(It is useful when using a heater).
Hi fan speed will not operate when using the air
circulation Fan mode.
Setting the Horizontal Airflow Direction
Adjust it manually
Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
P
O
W
E
R
P
O
W
E
R
T
I
M
E
R
T
I
M
E
R
Q
U
I
E
T
Q
U
I
E
T
P
O
W
E
R
F
U
L
P
O
W
E
R
F
U
L
P
O
W
E
R
F
U
L
P
O
W
E
R
F
U
L
E
C
O
N
O
M
Y
E
C
O
N
O
M
Y
E
C
O
N
O
M
Y
E
C
O
N
O
M
Y
P
O
W
E
R
P
O
W
E
R
T
I
M
E
R
T
I
M
E
R
Q
U
I
E
T
Q
U
I
E
T
MANUAL
Five stages of adjustment
can be made between
14 ~ 36 angle.
MANUAL
Five stages of adjustment
can be made between
0 ~ 61 angle.
Heat Pump Model
MANUAL
Five stages of adjustment
can be made between
14 ~ 36 angle.
MANUAL
Five stages of adjustment
can be made between
0 ~ 61 angle.
When the discharge air
temperature is low such
as at the start of heating
operation, the air blows
in a horizontal direction.
As the temperature
rises, the hot air blows
in a downward direction.
To stop this operation,
press MANUAL.
HEAT Operation
AUTO
COOL / DRY Operation
AUTO
Swing up/down
Automatically
36°
Swing up/down
Automatically
Move up/down
Automatically
36° 61°
COOL / DRY Operation
AUTO
FAN Operation
AUTO
Setting the Fan Speed
Press 4 to select:-
FAN Low Fan Speed
FAN Medium Fan Speed
FAN High Fan Speed
AUTO
FAN Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
Setting the Vertical Airflow Direction
Press 5 or 6 to select:-
Cooling Model
Use this air conditioner under the following
conditions:
Heat Pump Model
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature
Minimum Temperature
WBT
73.4
51.8
DBT
109.4
60.8
WBT
78.8
51.8
Indoor Outdoor
(Unit in °F)
DBT
89.6
60.8
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature-Cooling
(Maximum Temperature-Heating)
Minimum Temperature-Cooling
(Minimum Temperature-Heating)
DBT
89.6
(86)
60.8
(60.8)
WBT
73.4
()
51.8
()
DBT
109.4
(75.2)
60.8
(23)
WBT
78.8
(64.4)
51.8
(21.2)
Indoor Outdoor
(Unit in °F)
Cooling Model