Select an installation area that can support the total weight.
If a selected area is too weak to support the total weight, a fall of the product may occur
resulting in injury. Installation work shall be started after sufficient reinforcement.
Periodic inspections shall be conducted.
Rust on the metal parts or screws may cause a fall of the product resulting in injury. Consult
the dealer for the inspections.
Do not rub the edges of metal parts with your hand.
Failure to observe this may cause injury.
Consult the dealer about the installation area to select a strong ceiling area. Make sure that
the installation area is strong enough to hold the total weight of the camera assembly
(approx. 1.7 kg {3.6 lbs.}) before installation.
The installation area shall have 180 mm {7-1/8"} or more space behind the ceiling.
The thickness of the ceiling board for installation can range between 9 mm {3/8"} and
40 mm {1-9/16"}.
Avoid installing in the following locations.
Locations where it may get wet from rain or water splash (not only outdoor)
Locations where a chemical agent is used such as a swimming pool
Locations subject to steam and oil smoke such as a kitchen
Locations near flammable gas or vapor
Locations where radiation or x-ray emissions are produced
Locations subject to strong magnetic field or radio waves
Locations where it may be damaged by briny air such as seashores
Locations where the temperature is not within –10 °C - +50 °C {14 °F - 122 °F}.
Locations subject to vibrations (This product is not designed for on-vehicle use.)
Locations where the temperature may rapidly change such as the peripheral areas of
the air outlets of air conditioners or doors facing outside. (In case of installing the cam-
era in such locations, the dome cover may become foggy or condensation may be
caused on the cover.)
• The screws and bolts must be tightened with an appropriate tightening torque according to
the material and strength of the installation area. After tightening the screws or bolts, per-
form visual check to ensure tightening is enough and there is no backlash.
The pull-out strength of the installation area shall be 196 N {20 kgf} or more per 1 screw.
The protection sheet attached to the dome cover shall be peeled off after installation.
180 mm {7-1/8"} or more
Ceiling board: between 9 mm {3/8"}
and 40 mm {1-9/16"}