Panasonic 2008 Air Conditioner User Manual


 
Max. 30m
Pipe
length
Max. 20m
Level
difference
14 15
Feature Explanations
e-ion Air Purifying System Inverter Control
Quiet Mode
Powerful Mode
Ion Freshener
Patrol Sensor
Wide & Long Airflow Vane
Long Piping
Personal Airflow Creation
Random Auto Restart
Blue Fin Condenser
Self-Diagnostic Function
Top-Panel Maintenance Access
Conditions:
.
Our simulated-house facility 13.2m
2
.
Set temperature 25°C
Below 20
o
cBelow 20
o
c
Wide & Long Airflow Vane Conventional
Deodorising Filter
The photocatalytic filter absorbs odour
particles from cigarette smoke and pet
and household smells. The deodorisation
effect is regenerated when the filter is
exposed to sunlight.
Manual Horizontal Airflow
Direction Control
Auto Changeover (Inverter)
Auto Changeover
Soft Dry Operation Mode
Hot Start Control
Airflow Direction Control
(Up & Down)
Starts with cooling to dehumidify.
Then provides continuous breeze at low
frequency to keep room dry without
much change in temperature.
On the start of heating cycle and after
defrost cycle, the indoor fan will start up
once the indoor heat exchanger is warm.
Every period
* at "AUTO" operation
Set
temperature
Room
temperature
Outdoor
temperature
Auto Changeover System
Heat Dry Cool
Checks three temperatures.
Evaluates the three temperatures
and selects the operating mode
accordingly.
Active e-ions are shot out to catch dust
and inactivate airborne bacteria and
mould. The positively charged mega
filter attracts dust to thoroughly clean
the room.
It is known that areas rich in negative
ions, like near waterfalls and forests,
generally make people feel refreshed.
With Panasonic split air conditioner, the
same refreshing feeling can be felt just
by pushing a single button.
Healthy Air Quality Comfortable
Reliable
An inverter air conditioner provides
optimum power control, which is
impossible for conventional units. The
secret lies in the inverter circuit. By
changing the frequency of power supply,
this circuit alters the rotation speed of
the compressor, which is the heart of the
air conditioner. The result is comfortable,
economical air conditioning.
Odour-Removing Function
With this function, there's no unpleasant
odour when the unit starts up. That's
because the fan remains off momentarily,
while the source of the odour inside the
air conditioner is suppressed.
*The unit must be in cool or dry mode and the fan speed
must be set to automatic.
Removable, Washable Panel
Anti-Mould, One-Touch Air Filter
The front panel is easy to keep clean. It
removes quickly with a simple one-step
operation and can be washed in water.
A clean front panel promotes smoother,
more efficient performance, which can
save energy.
The Quiet Mode reduces both indoor and
outdoor unit operating sound.
This function is especially convenient for
operation near a sleeping baby and at
night-time.
mode
Pressing the Powerful button cools or
heats the room quickly. It provides fast
comfort, with full power and a strong
airflow. This is perfect for use
immediately after coming home, or
when unexpected guests arrive.
Vertical and horizontal air flow patterns
can be combined as desired to gain the
greatest possible comfort, with
operation possible even from a distance
by remote control.
All models are now safe to operate without a
starter. With the exclusive Random Auto Restart
feature, the air conditioners automatically restart
after power failure. Its 32 different recovery-timing
patterns ensure that air conditioners in the same
building resume one after another instead of all at
the same time. This feature helps prevent power
surges after a blackout and walls are nearer too.
Maintenance of the outdoor unit used to be quite a
tedious chore, especially when the unit was
installed on a narrow balcony or attached to the
outer wall of a high-rise building.
Should a malfunction occur, the unit diagnoses
the problem and shows the corresponding
alphanumeric code. This allows quicker servicing.
The basic piping can be extended,
allowing the outdoor unit to be installed
farther away from the
indoor unit and
providing greater
installation flexibility.
• Up & Down Airflow —
5 Patterns + Auto
• Left & Right Airflow —
5 Patterns + Auto
When you don't want
airflow directed right
at you.
When you want direct
airflow.
When you want to
warm yourself
thoroughly from the
feet up.
To focus the airflow to
one side of the room.
To focus the airflow to
the centre.
For uniform airflow
throughout the room.
Supersonic Air Purifying System
Supersonic Air Purifying Device
SUPER alleru-buster filter
Supersonic wave generator
The Supersonic Air Purifying System
incorporated in the indoor unit generates
supersonic waves. The system works in
combination with the filter to collect dust and dirt
in the air for faster, more efficient air purification.
*The graph refers to the CS-E28GKR *Extendable length varies
by model. *If the piping is extended past the basic pipe length,
there's an extra charge for additional refrigerant.
Not all features found on all models.
Air is monitored both during air
conditioner operation and when it’s
switched off. When dirt is detected, the
air purifying
function is started
to immediately
clean the air in the
room.
SUPER alleru-buster filter
The SUPER alleru-buster filter combines
three effects in one — anti-allergen,
anti-virus, and anti-bacteria protection —
to keep room air clean and healthful.
Inactivates more than
99%
of all filter-captured allergens
Inactivates more than
99%
of all filter-captured viruses
Anti-allergen protection
Anti-virus protection
Enzymatic action eliminates more than
99%
of all filter-captured bacteria
Anti-bacteria/Anti-mould protection
Here, inactivate means to suppress normal activity. This
inactivation of mite allergens has been verified by the
University of Edinburgh in the UK.
This newly designed vane has been
integrated with the louver to send the air
further. Sends air to every
corner of the room to
keep the whole room
comfortable.
Condensers can take a beating from exposure
to salty air, rain and other corrosive factors.
Panasonic has tripled the life of our condensers
with an original anti-rust coating.
Blue Fins
Front View
Side View
Non-Blue Fins
1. Matsushita Air Conditioning R&D Centre Sdn. Bhd.
2. A third party authorized research institute in Malaysia.
Special Coating Layer
(Fin Cross-section)
Cyclic Corrosion Test Results
Water Air
Salt
content
Base material
Corrosion-
resistant layer
Indoor unit:
As quiet as a library
Outdoor unit:
Approx.
21dB
Approx.
41
dB
20dB 40dB
* Based on in-house Panasonic measurement standards
As quiet as a sound of
leaves on a tree
ISO 9001 Certification
CERTIFIED TO MS ISO 9001: 2000
Panasonic HA Air-Conditioning (M) Sdn.
Bnd. (PHAAM)
Registration No.: AR 1010
This Panasonic air conditioner factory in Malaysia has received
ISO 9001 certication. ISO 9001 Certication attests to the
excellent quality assurance systems in place at this factory.
About ISO 9001 Certification
ISO 9001 certication is granted only when thorough
examination has shown that products are designed,
manufactured, marketed and serviced by a system of quality
that is complied with the internationally recognized ISO 9001
quality assurance standard. The Malaysian factory was
certied by the world renowned SIRIM organization.
CERTIFIED TO MS ISO 14001: 2004
Panasonic HA Air-Conditioning (M) Sdn.
Bnd. (PHAAM)
Certication No.: P06860001
Environmental Management
Systems Approval
Certificate
MS ISO 14001 CERT. NO. P06860001
Standard Warranty
This was tested by:
ENVIRONMENTAL
SYSTEM
SIRIM
074
24-Hour ON & OFF Real Setting Timer
LCD Wireless Remote Controller
Convenient
The start or stop operation time (hour
and minute) can be set at one time.
Or both of the times for start and stop
operation can be set.
CS : Split Type (Indoor unit)
CU : Split Type (Outdoor unit)
CZ : Accessories
Model Type
1
E : Inverter Reverse Cycle
W : Reverse Cycle
Function
2
Value = Capacity (Btu/h) x 1/1000e.g.
18,000 Btu/h x 1/1000 = 18
Capacity
4
K : Wall-Mounted Type
Type
3
E G K RCU
2
9
3
1
4
The System of Model Numbers for Split Models