Sylvania 070282 Electric Heater User Manual


 
OPERATING INSTRUCTIONS
OSRAM
8/12/00
SYLVANIA
Process Heat
131 Portsmouth Ave. Exeter, NH 03833 USA Tel: 800-258-8290 Fax: 603-772-1072
1
G-TEMP HEATER
065253, 066136, 070282
FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.
Description
!
Compact, efficient heater with integrated temperature and power controller for heating air or inert gases to
1300°F (700°C). A thermal sensor in the control box turns the heater power off if airflow is lost, or the inlet air
temperature is too high. A built-in airflow damper controls airflow, and control potentiometer controls
temperature. If operated correctly, the heater will operate continuously for 5000 hours or longer.
Specifications
MAXIMUM INLET PRESSURE 2 PSI (.14 BAR)
MAXIMUM INLET AIR TEMPERATURE 100°F (38°C)
MAXIMUM EXIT AIR TEMPERATURE 1300°F (760°C)
MODEL
NUMBER
MAXIMUM
WATTAGE
SUPPLY
VOLTAGE
AMP
RATING
REPLACEMENT
ELEMENT
NUMBER
066136 1500 120 - 60 Hz 13 066137
065253 3000 230 - 60 Hz 15 065335
070282 3000 230 - 50 Hz 15 065335
Safety
!
SHOCK HAZARD Only qualified individuals should install this heater and related controls. Follow all applicable
electrical codes and use proper wiring.