Omega WMS-T-AL Home Security System User Manual


 
MENU STRUCTURE
The user interface contains the following menu items:
• Temperature Alarms
Alarm Delays
Maximum/Minimum Temperature
The MENU Button
The MENU button will take the unit out of the RUNNING mode and allow the user to change
the operating parameters and view maximum values.
Once the MENU button has been pressed t
he user may use the UP and DOWN buttons to scroll
through the menu.
Subsequent presses of the MENU button will bounce the cursor between editable fields of any
menu item, where applicable. When in an editable field, the cursor will become a blinking
b
lock.
The GO Button
The GO Button always returns the unit to the RUNNING mode, regardless of where the user
may be in the menu structure.
The UP and DOWN Buttons
The UP and DOWN buttons control either of two things:
1. Scrolling through menu items when the user is not in an editable field.
2. Scrolling through
user selectable values when the user is in an editable field.
The CLEAR Button
Pressing the CLEAR button performs the following actions:
1. If the user is in an editable field, the field will be set to 0.
2. It the user is viewing the maximum/minimu
m temperature value, the recorded
value will be cleared.
3. If the unit is alarming, all delay counters will be cleared.
ALARM Features
The WMS-T-AL Temperature Alarm provides the following alarm features:
Two independent temperature alarms
Programmable On and OFF delays
Pausing of alarm when any key is pressed
2