Adjustments
Consistency Adjustment:
1. Unplug the machine.
2. Be sure that product in the bowl is within proper fill range.
(Above the minimum fill line) Remove merchandiser.
3. Change the thickness of the product by turning the screw on the
back of the bowl, as shown on fig. Turn the screw clockwise for thinner
product or counterclockwise for thicker product, (+) thicker, (-) thinner.
Each bowl has its own adjusting screw.
Cleaning Procedures
Disconnect the unit from the power supply before sanitizing and cleaning.
Failure to do so may result in electric shock.
Daily Cleaning: For the machine to function properly, it is important that
the cleaning procedures be carried out daily, according to the following
instructions:
Turn off the equipment and empty the bowl of its remaining product. After
draining the product from the unit, you can fill the bowl with hot water
(not boiling) to help melt off any sugar deposits. Drain the water prior to
proceeding to the next step. To disassemble the draw valve, extract the
pin from its seat and the rest of the parts will come out. Wash them with
care in warm water.
Remove the bowl by lifting the front part until released, then gently hit on
the rear side to completely remove it. Take off the bowl, the spiral agitator
and the rear gasket.
6