Omega HPP-600 Water Pump User Manual


 
For High Pressure Operation
Prior to pressurizing, back out the Vernier knob until the ring on the Vernier shaft
is showing. Pump to pressurize. Turn the Vernier knob towards the pump
housing and the pressure should easily be able to reach 600 psi.
NOTE:
The pump uses a Schrader valve instead of a needle valve. Thus, full open or
closed is several turns from the end of the travel. Over-tightening does not
increase the seal.
Fittings
The pump is equipped with 1/8" and 1/4" BSP ports. In order to use NPT fittings, a
NPT to BSP Parallel Thread Adapter is required. These adapters, which are
included with the pump, have a bonded washer attached to the male end of the
adapter.
MAINTENANCE
No routine maintenance is required. A periodic check of system calibration is
recommended
. The Pump is not field serviceable and should be returned to
Omeg
a Engineering if repair is needed (field repair should not be attempted and
ma
y void warranty). Be sure to include a brief description of the problem plus
an
y relevant application notes. Contact customer service to receive a return
goods authorization number before shipping.
Servicing North America:
U.S.A.: One Omega Drive, Box 4047
ISO 9001 Certifie
d Stamford, CT 06907-0047
Tel: (203) 359-1660
FA
X: (203) 359-7700
e-mail: info@omega.com
Canada:
976 Bergar
Laval (Quebec) H7L 5A1, Canad
a
Tel: (514) 856-6928
FA
X: (514) 856-6886
e-mail: info@omega.c
a
For immediate technical or application assistance:
U.S.A. and Canada:
Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico:
En Espan˜ol: (001) 203-359-7803
FAX: (001) 203-359-7807
e-mail: espanol@omega.com
info@omega.com.mx
Servicing Europe:
Czech Republic:
Frystatska 184, 733 01 Karvina´, Czech Republic
Tel: +420 (0)59 6311899
FA
X: +420 (0)59 6311114
Toll Free: 0800-1-66342
e-mail: info@omegashop.cz
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel: +49 (0)7056 9398-0
FA
X: +49 (0)7056 9398-29
Toll Free in Germany:
0800 639 7678
e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9001 Certified
Northbank, Irlam, Manchester
M44 5BD United Kingdom
Tel: +44 (0)161 777 6611
FA
X: +44 (0)161 777 6622
Toll Free in United Kingdom: 0800-488-488
e-mail: sales@omega.co.uk
OMEGAnet
®
On-Line Service Internet e-mail
omega.com info@omega.com
FOR WARRANTYRETURNS, please have the following
information available BEFORE contacting OMEGA
:
1. Purchase Order number under which the product wa
s
PURCHASED
,
2. Model and serial number of the product under
warranty, and
3. Repair instructions and/or specific problems relative to the
product.
FOR NON-WARRANTYREPAIRS,
consult OMEGA for current repair
charges. Have the following information available BEFORE
contacting OMEGA
:
1. PurchaseOrder number to cover the COST of the repair,
2. Model and
serial number of the product, and
3. Repair instructions and/or specific problems relative to the
product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the lat-
est in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC
.
© Copyright 2008 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or
reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from
date of purchase. OMEGA’s
WARRANTY adds an additional one (1) month grace period to the normal one (1) year product
warrantyto cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s
Customer Service Department will issue an
Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be
defective, it will be repaired or replaced at no charge. OMEGA’s
WARRANTY does not apply to defects resulting from any action of the
purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair,
or
unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of
having been damaged as a result of excessive
corrosion; or current, heat, moisture or vibration; improper specification;
misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted,
include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes
responsibility for any omissions or errors nor assumes liability for any damages that result from the use of it
s
products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that th
e
parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIE
S
OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT
OF TITLE, AND ALL
IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE
ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are
exclusive,
and the total liability of OMEGA with respect to this order, whether based on contract, warranty,
negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon
which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CF
R
21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s
)
be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way,
OMEGA assumes
no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA
and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/ INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY
PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN
AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER
SERVICE DEPART
MENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the
outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its products to the European Ne
w
Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering,
Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications
without notice. WARNING: These products are not designed for use in, and should not be used
for, human applications.