NuTone LA-58 Door User Manual


 
COMMON
TRANSFORMER
SIDE
REAR
FRONT
8
4
8 OR 4 NOTE
SELECTOR
SWITCH
SOFT
LOUD
VOLUME
37989
CAUTION: DO NOT CONNECT
OR DISCONNECT WIRES
WITH POWER APPLIED TO
TRANSFORMER
FOR USE WITH 16vAC
TRANSFORMER
COMMON
TRANSFORMER
SIDE
REAR
FRONT
8
4
8 OR 4 NOTE
SELECTOR
SWITCH
SOFT
LOUD
VOLUME
37989
CAUTION: DO NOT CONNECT
OR DISCONNECT WIRES
WITH POWER APPLIED TO
TRANSFORMER
FOR USE WITH 16vAC
TRANSFORMER
Connect clock leads
or light leads to
terminal board
attached to chassis
(not shown).
(Where applicable.)
COMMON
TRANSFORMER
SIDE
REAR
FRONT
8
4
8 OR 4 NOTE
SELECTOR
SWITCH
SOFT
LOUD
VOLUME
37989
CAUTION: DO NOT CONNECT
OR DISCONNECT WIRES
WITH POWER APPLIED TO
TRANSFORMER
FOR USE WITH 16vAC
TRANSFORMER
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
®
Decorator
Door Chimes
LB-46, LD-49, LA-58, LA-70MA,
& LA-151WM SERIES
Your NuTone Door Chime is designed for three (3) door
operation. It will sound either 8 or 4 notes for the front door,
one (1) note for a second door and a different note for a third
door. Use the NuTone transformer packaged with the chime
for best results.
When installing this chime and wiring has been completed,
check to make sure that the pushbuttons are in good
operating condition. When installed correctly, they must not
stick – meaning they must return to the original position to
open the circuit.
FIGURE 1
FIGURE 2
One Chime using the Transformer supplied.
To 115V 50/60 Hz A.C.
Power Supply
Rear
Door
Push-
button
Side Door
Pushbutton
Front Door
Pushbutton
CAUTION: Do not
connect or disconnect
wires with power
applied to transformer
Transformer
For 2 Door Operation
Do Not Connect
Side Door
Terminal
Panel on
Back of
Chime
Two Electronic Chimes using two (2) Transformers, connected in phase. Transformers
are packaged with the chimes or use one (1) NuTone Model: 301-N Transformer.
To 115V
50/60Hz A.C.
Power Supply
Rear
Door
Push-
button
Front
Door
Push-
button
Side
Door
Push-
button
Transformer
FRONT
TRANSFORMER
REAR
COMMON
TRANSFORMER
SIDE
REAR
FRONT
8
4
8 OR 4 NOTE
SELECTOR
SWITCH
SOFT
LOUD
VOLUME
37989
CAUTION: DO NOT CONNECT
OR DISCONNECT WIRES
WITH POWER APPLIED TO
TRANSFORMER
FOR USE WITH 16vAC
TRANSFORMER
FIGURE 3
To 115V
50/60Hz A.C.
Power Supply
Rear Door
Pushbutton
Side Door
Pushbutton
Front Door
Pushbutton
Transformer
One Electronic Chime with one 2-Note Chime
HELPFUL HINTS – This chime is "protection
packed". Handle carefully as you would any
precision instrument. Comply with local wiring
codes when wiring the chime. Upon
completion of the installation, if the chime does
not operate, recheck your installation with these
instructions and wiring diagram. If the chime
still does not operate, check the pushbutton(s)
for poor contact or loose connections.
INSTALLATION
Select a central location to insure an audible
signal throughout the home. For a large ranch-
style or multi-story home, two chimes may be
needed. Refer to Figures 2 and 3 for Multiple
Chime Wiring Information.
WIRING
NOTE: BE SURE HOUSE POWER IS TURNED OFF WHEN
INSTALLING THE TRANSFORMER.
1. Mount the transformer to a convenient junction box (attic location
is not recommended) or circuit breaker box. Connect the
transformer leads to house power leads: black to black and
white to white.
IMPORTANT: All wiring connections must comply with
national or local codes. Run two conductor, 18 gauge wire from
the transformer and pushbuttons to the chime location. Bring wires
through wiring access hole in the chime baseplate and fasten the
baseplate to the wall with screws provided. Connect wires to
chime terminal board as illustrated in Figure 1. For two chime
installation refer to Figure 2. For one chime with one two-note
chime, refer to Figure 3.