INSTALLATION
• Installation instructions included with each unit.
• “A” unit and “B” unit are packed in a master carton to
permit installation of each assembly as required. “A” unit
installs in 11
1
8
" diameter opening in wood or masonry
walls during rough-in or in a finished wall.
• The outlet box, removable for installation behind plaster
or drywall, features three (3) knockouts to permit wiring
from above or below the unit. The outlet box and switch
are prewired at the factory; connect house leads to
complete the wiring connections. Installation Instructions
are included with each unit.
• Install at least 5 feet above floor or install above counter
or major appliance.
DIMENSIONS
TYPICAL INSTALLATIONS
13
3
4
" SQ.
FAN HOUSING
SQUARE
PANEL
PLASTER
LINE
ROUND
OPENING
IN WALL
BRICK WALL
WOOD WALL
10
3
4
"
11
3
4
"
PULL CHAIN
OUTLET
BOX
7
8
" KNOCKOUT
ADJUSTABLE
SLEEVE
1
1
4
"
OUTSIDE WALL
PLATE
SHUTTER
13
1
2
"
13
1
2
"
5" TO 10"
MOTOR ASSEMBLY
MOUNTING
BRACKET
PLUG-IN MOTOR
ASSEMBLY
10" BLADES
SQUARE
PANEL
PLASTER
LINE
ROUND
OPENING
IN WALL
Product specifications subject to change without notice.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A.