Page 3
MODEL 765HFL
8. Plug-in
light.
Hold grille
assembly up near
housing. Connect
light plug from
grille assembly to
receptacle inside
of housing.
INSTALL GRILLE & BULBS
9. Attach
grille.
Place grille/
reector
combination
over protruding
screw and
fasten in place
using acorn nut
provided. HAND
TIGHTEN acorn
nut 1/4 turn after
it is snug.
10. Install bulb.
The unit accepts
a 27-Watt,
3500K, GU24
uorescent
lamp. Insert tabs
on lamp base
into slots in lamp
receptacle and
gently twist lamp
clockwise.
11. Attach
light lens.
Hook the tabs
on one end of
the lens into the
slot in the grille.
Lift other end
of lens up and
snap into place.
5. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connectors to secure house wiring to
wiring plate. Connect wires as shown in wiring diagram(s).
CONNECT WIRING
B L U
B L K
B L K
W H T
W H T
W H T
R E D
W H T
G R D
U N I T
L I G H T
S W I T C H
V E N T
S W I T C H
H E A T
S W I T C H
L I N E
I N
R E D
B L K
W H T
B L K
W H T
G R D
DOU BLE- GANG SW ITCH BOX
LIG HT
VEN T
HEAT
INSTALL GRILLE & BULB
7. Remove
light lens
from grille.
Insert a small
at-bladed
screwdriver into
the slot at one
end of the light
lens. Carefully pry
the lens out.
6. Finish ceiling.
Install ceiling material. Cut out ceiling material closely
around housing.
GREEN
WHITE
to
WHITE
HEAT
LIGHT
GROUND
120 VAC LINE IN
BLACK
BLACK
FAN
RED
WIRING PLATE
FROM VENTILATOR
VENTILATOR
HOUSING
LIGHT
&
FAN
HEAT
BLACK to BLACK
(Fan)
WHITE to WHITE
RED to BLUE
(Light)
BLACK to RED
(Heat)
WHITE to WHITE
BLACK
CAUTION
RATING
SPECIFICATIONS
Each two-position rocker
switch is rated 15 A @
120VAC. The total load
on this control must not
exceed 20 A @ 120VAC.
SCREW
GRILLE
ACORN NUT
LIGHT
REFLECTOR
BOTTOM VIEW
USE
THIS
HOLE