HVI-2100 CERTIFIED RATINGS comply with new testing
technologies and procedures prescribed by the Home Ventilating
Institute, for off-the-shelf products, as they are available to
consumers. Product performance is rated at 0.1 in. static pressure,
based on tests conducted in a state-of-the-art test laboratory.
Sones are a measure of humanly-perceived loudness, based on
laboratory measurements.
SPECIFICATIONS
MODEL VOLTS AMPS*
744SFLNT 120 0.7
STATIC PRESSURE CFM SONES FAN WATTS DUCT
0.10 70 1.5 34.4 4” Round
0.25 55
* Total Connected Load
INSTALLATION
Complete installation instructions are included with each Humidity
Sensing Recessed Fan / Light.
TYPICAL SPECIFICATION
Fan / Light shall be NuTone Model 744SFLNT as manufactured by
NuTone according to specifications listed:
Fan / Light shall have corrosion resistant steel housing and adjustable
mounting brackets.
Motor assembly to be removable and permanently lubricated.
Non-metallic damper/duct connector to be included.
Fan and Light to operate separately or in combination.
Fan / Light must use an R30-shaped, 2700K, 16W, high efficacy,
GU24-based, compact fluorescent lamp.
Air delivery shall be no less than 70 CFM and sound level no greater
than 1.5 Sones. All air and sound ratings shall be certified by HVI.
Fan / Light must be U.L. and cU.L. Listed for use in insulated ceilings
(Type I.C.).
Fan / Light must be Title 24 compliant.
Fan / Light must be ENERGY STAR qualified.
The unit will have a control that will automatically turn fan ON
when humidity increase is rapid to moderate (user adjustable), or
when humidity is higher than user-adjustable set-point (50%-80%
Relative Humidity), or when supply power is cycled from ON (for
more than a second) to OFF (for less than a second) and back
ON. It shall be user-adjustable to turn OFF 5 to 60 minutes after
humidity has stabilized and is below user-adjustable set-point, or
after manually initiated by supply power cycling.