REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 800-558-1711
Broan-NuTone Canada Missisauga, Ontario www.nutone.ca 877-896-1119
Architectural & Engineering Specifications
August 2012
Humidity Sensing
Recessed
Fan / Fluorescent
Light
21H 99044980B
DESCRIPTION
TRIM RING BAFFLE:
•
Polymeric construction with matte white finish
•
Recessed styling, mounts flush with finished ceiling
•
Integrated humidity sensor
LAMP:
•
Uses R30-shaped, 2700K, 16W, high efficacy, compact
fluorescent lamp with GU24 base (included)
BLOWER:
•
Plug-in, permanently lubricated, motor
•
Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
•
Quiet operation
HOUSING:
•
Fits in 2” x 8” construction
•
Rugged, 26 gage, galvanized steel construction
•
4” round, polymeric duct connector with 2” tapered sleeve and
no metallic clatter
•
Adjustable mounting brackets span up to 24”
CONTROLS: (purchase separately)
•
Model VS-96 - One rocker switch with “on” indicator light
•
Model VS-86SN - Two rocker switches - fits single outlet box
AUTOMATIC CONTROL:
•
Humidity control automatically turns fan ON when either of
these conditions is detected:
- a rapid to moderate (user adjustable) increase of humidity
- humidity above user-adjustable set-point (50%-80% RH)
•
Two wire manual operation for odor control - Turns fan ON
when power line through wall switch is cycled ON, OFF and
back ON
•
Remains ON for a user-adjustable 5 to 60 minutes after
humidity has stabilized and is below set-point or after
manually initiated through power line cycling
•
Saves energy because unit runs only for the time required. A
unit controlled with a wall timer may keep fan ON longer than
required or turn it OFF before room is sufficiently ventilated
U.L. Listed for use in insulated ceilings (TYPE I.C.)
U.L. Listed for use over bathtubs and showers when connected to
a GFCI protected branch circuit.
Title 24 compliant.
ENERGY STAR qualified.
MODEL 744SFLNT