Lifebreath AH60DHW Water Heater User Manual


 
19
JUMPER
PUMP TIMER (OPTIONAL)
1 LOAD
2 LINE
3 ..
4
5
RWC
YG
24VAC THERMOSTAT CONNECTIONS
GND
TRANSFORMER
24V
NC
NO
NO C
C
NC
120V
LINE
NEUTRAL
NO
NC
com
HIGH
Speed Select
red
white
blue
black
yellow
Door Interlock
Switch
3
0
2
0
FAN MOTOR
FAN
CAPACITORS
PUMP
black
yellow
blue
MED-HIGH
MED
Field
Connection
Wire Nut
AH-02
0211
Wire Nut
WARNING
1 AMP
MAX
FUSE
* TEMPERATURE
SENSOR
* NOTE: Units with
an (Optional) Pump
Timer do not get an
(
Optional) Temperature
Sensor
12345
The Air Handler operates at 120V, singles phase
and draws anywhere from 2-8.7 amps,
depending on fan speed.
The low voltage thermostat (not provided)
connects to the R & W terminals for heating and
the R & Y & C terminals when calling for cooling.
Caution should be used if installing a setback
thermostat to control the system. If the
thermostat is set back too far, and, for example,
is set to call for a lot of heat when you get out of
bed, at which time showering and general water
use is at its peak, then the hot water heater may
not keep up.
Air Handler - Wiring Diagram
To change fan speed,
move bottom wires on
the speed select terminal
block to the high, med-hi
or med location.
Note: Unit is shipped
on high speed.
R - W = Heat
R - G = Fan Only (optional dehumidistat)
G - R - Y - C = A/C
Electrical